S912XET512J3VALR Freescale Semiconductor, S912XET512J3VALR Datasheet - Page 498

no-image

S912XET512J3VALR

Manufacturer Part Number
S912XET512J3VALR
Description
16-bit Microcontrollers - MCU 16 BIT,512K FLASH
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S912XET512J3VALR

Rohs
yes
Core
HCS12X
Processor Series
MC9S12XE
Data Bus Width
16 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
512 KB
Data Ram Size
32 KB
On-chip Adc
Yes
Operating Supply Voltage
3.13 V to 5.5 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
LQFP-112
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S912XET512J3VALR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Chapter 11 S12XE Clocks and Reset Generator (S12XECRGV1)
11.6.1
11.6.1.1
The S12XECRG generates a real time interrupt when the selected interrupt time period elapses. RTI
interrupts are locally disabled by setting the RTIE bit to zero. The real time interrupt flag (RTIF) is set to1
when a timeout occurs, and is cleared to 0 by writing a 1 to the RTIF bit.
The RTI continues to run during Pseudo Stop Mode if the PRE bit is set to 1. This feature can be used for
periodic wakeup from Pseudo Stop if the RTI interrupt is enabled.
11.6.1.2
The S12XECRG generates a IPLL Lock interrupt when the LOCK condition of the IPLL has changed,
either from a locked state to an unlocked state or vice versa. Lock interrupts are locally disabled by setting
the LOCKIE bit to zero. The IPLL Lock interrupt flag (LOCKIF) is set to1 when the LOCK condition has
changed, and is cleared to 0 by writing a 1 to the LOCKIF bit.
11.6.1.3
The S12XECRG generates a Self Clock Mode interrupt when the SCM condition of the system has
changed, either entered or exited Self Clock Mode. SCM conditions are caused by a failing clock quality
check after power on reset (POR) or low voltage reset (LVR) or recovery from Full Stop Mode (PSTP =
0) or Clock Monitor failure. For details on the clock quality check refer to
Checker”. If the clock monitor is enabled (CME = 1) a loss of external clock will also cause a SCM
condition (SCME = 1).
SCM interrupts are locally disabled by setting the SCMIE bit to zero. The SCM interrupt flag (SCMIF) is
set to1 when the SCM condition has changed, and is cleared to 0 by writing a 1 to the SCMIF bit.
498
Description of Interrupt Operation
Real Time Interrupt
IPLL Lock Interrupt
Self Clock Mode Interrupt
MC9S12XE-Family Reference Manual Rev. 1.25
Section 11.4.1.4, “Clock Quality
Freescale Semiconductor