C8051F360DK Silicon Laboratories Inc, C8051F360DK Datasheet - Page 183

KIT DEV FOR C8051F360 FAMILY

C8051F360DK

Manufacturer Part Number
C8051F360DK
Description
KIT DEV FOR C8051F360 FAMILY
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F360DK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051F36x
Interface Type
USB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F360, F361, F362, F363, F364, F365, F366, F367, F368, F369
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1410
17. Port Input/Output
Digital and analog resources are available through up to 39 I/O pins. On the largest devices
(C8051F360/3), port pins are organized as four byte-wide Ports and one 7-bit-wide Port. On the other
devices (C8051F361/2/4/5/6/7/8/9), port pins are three byte-wide Ports and one partial port. Each of the
Port pins can be defined as general-purpose I/O (GPIO) or analog input/output; Port pins P0.0–P3.7 can
be assigned to one of the internal digital resources as shown in Figure 17.3. The designer has complete
control over which functions are assigned, limited only by the number of physical I/O pins. This resource
assignment flexibility is achieved through the use of a Priority Crossbar Decoder. Note that the state of a
Port I/O pin can always be read in the corresponding Port latch, regardless of the Crossbar settings.
The Crossbar assigns the selected internal digital resources to the I/O pins based on the peripheral priority
order of the Priority Decoder (Figure 17.3 and Figure 17.4). The registers XBR0 and XBR1, defined in SFR
Definition 17.1 and SFR Definition 17.2, are used to select internal digital functions.
All Port I/Os are 5 V tolerant (refer to Figure 17.2 for the Port cell circuit). The Port I/O cells are configured
as either push-pull or open-drain in the Port Output Mode registers (PnMDOUT, where n = 0,1,2,3,4). Com-
plete Electrical Specifications for Port I/O are given in Table 17.1 on page 201.
Highest
Priority
Lowest
Priority
Figure 17.1. Port I/O Functional Block Diagram (Port 0 through Port 3)
SYSCLK
Outputs
SMBus
T0, T1
UART
P0
P1
P2
P3
PCA
CP0
CP1
SPI
(P0.0-P0.7)
(P1.0-P1.7)
(P2.0-P2.7)
(P3.0-P3.7)
2
4
2
4
7
2
8
8
8
8
PnSKIP Registers
XBR0, XBR1,
Crossbar
Decoder
Priority
Digital
C8051F360/1/2/3/4/5/6/7/8/9
Rev. 1.0
8
8
8
8
P1MASK, P1MATCH,
P0MASK, P0MATCH
P2MASK, P2MATCH
Registers
Cells
Cells
Cells
Cell
I/O
I/O
I/O
I/O
P0
P1
P2
P3
PnMDIN Registers
PnMDOUT,
3.5–3.7 available on
C8051F360/3
P0.0
P0.7
P1.0
P1.7
P2.0
P2.7
P3.0
P3.7
C8051F360/1/3/4/6/8
3.1–3.4 available on
183

Related parts for C8051F360DK