KSZ8863FLLI Micrel Inc, KSZ8863FLLI Datasheet - Page 41

no-image

KSZ8863FLLI

Manufacturer Part Number
KSZ8863FLLI
Description
IC ETHERNET SWITCH 3PORT 48-LQFP
Manufacturer
Micrel Inc
Datasheet

Specifications of KSZ8863FLLI

Controller Type
Ethernet Switch Controller
Interface
MII
Voltage - Supply
1.8V, 2.5V, 3.3V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Lead Free Status / RoHS Status
Supplier Unconfirmed, Lead free / RoHS Compliant
Other names
576-3750

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8863FLLI
Manufacturer:
Micrel
Quantity:
446
Part Number:
KSZ8863FLLI
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8863FLLI
0
Micrel, Inc.
KSZ8863MLL/FLL/RLL
Loopback Support
The KSZ8863MLL/FLL/RLL provides loopback support for remote diagnostic of failure. In loopback mode, the speed at
both PHY ports needs to be set to 100BASE-TX. Two types of loopback are supported: Far-end Loopback and Near-end
(Remote) Loopback.
Far-end Loopback
Far-end loopback is conducted between the KSZ8863MLL/FLL/RLL’s two PHY ports. The loopback is limited to few
package a time for diagnosis purpose and can not support large traffic. The loopback path starts at the “Originating.” PHY
port’s receive inputs (RXP/RXM), wraps around at the “loopback” PHY port’s PMD/PMA, and ends at the “Originating”
PHY port’s transmit outputs (TXP/TXM).
Bit [0] of registers 29 and 45 is used to enable far-end loopback for ports 1 and 2, respectively. Alternatively, the MII
Management register 0, bit [14] can be used to enable far-end loopback.
The far-end loopback path is illustrated in the following figure.
Figure 14. Far-End Loopback Path