Datasheet

Specifications of KSZ8863FLLI

Controller Type
Ethernet Switch Controller
Interface
MII
Voltage - Supply
1.8V, 2.5V, 3.3V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Lead Free Status / RoHS Status
Supplier Unconfirmed, Lead free / RoHS Compliant
Other names
576-3750

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8863FLLI
Manufacturer:
Micrel
Quantity:
446
Part Number:
KSZ8863FLLI
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8863FLLI
0
Micrel, Inc.
Register 8 (0x08): Global Control 6
Register 9 (0x09): Global Control 7
Register 10 (0x0A): Global Control 8
Register 11 (0x0B): Global Control 9
Register 12 (0x0C): Global Control 10
Register 13 (0x0D): Global Control 11
September 2009
Bit
7-0
7-0
7-0
7-6
5-4
3-2
7-6
5-4
3-2
1-0
7-6
5-4
3-2
1-0
Bit
Bit
Bit
Bit
Bit
1
0
Testing
Testing
Testing
CPU interface
Clock
Selection
Reserved
Reserved
Name
Factory
Name
Factory
Name
Factory
Name
Reserved
Reserved
Name
Tag_0x3
Tag_0x2
Tag_0x1
Tag_0x0
Name
Tag_0x7
Tag_0x6
Tag_0x5
Tag_0x4
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
RO
RO
RO
RO
RO
RO
RO
Description
IEEE 802.1p mapping. The value in this field is used as the frame’s
priority when its IEEE 802.1p tag has a value of 0x7.
IEEE 802.1p mapping. The value in this field is used as the frame’s
priority when its IEEE 802.1p tag has a value of 0x6.
IEEE 802.1p mapping. The value in this field is used as the frame’s
priority when its IEEE 802.1p tag has a value of 0x5.
IEEE 802.1p mapping. The value in this field is used as the frame’s
priority when its IEEE 802.1p tag has a value of 0x4.
Description
IEEE 802.1p mapping. The value in this field is used as the frame’s
priority when its IEEE 802.1p tag has a value of 0x3.
IEEE 802.1p mapping. The value in this field is used as the frame’s
priority when its IEEE 802.1p tag has a value of 0x2.
IEEE 802.1p mapping. The value in this field is used as the frame’s
priority when its IEEE 802.1p tag has a value of 0x1.
IEEE 802.1p mapping. The value in this field is used as the frame’s
priority when its IEEE 802.1p tag has a value of 0x0.
Description
=00, 31.25MHz supports SPI speed below 6MHz
=01, 62.5MHz supports SPI speed between 6MHz to 12.5MHz
=10, 125MHz supports SPI speed above 12.5MHz
Note: Lower clock speed will save more power consumption, It is
better set to to 31.25MHz if SPI doesn’t request a high speed.
N/A Don’t change
N/A Don’t change
N/A Don’t change
N/A Don’t change
Description
Reserved
Do not change the default values.
Description
Reserved
Do not change the default values.
Description
Reserved
Do not change the default values.
53
KSZ8863MLL/FLL/RLL
Default
Default
Default
Default
Default
Default
0x00
0x24
0x35
11
11
10
10
10
00
10
01
01
00
00
0