8.6.26 Word 93: Ultra DMA Modes Supported and Selected (if supported)
Word 93 shows Hardware reset result. The contents of bits (12:0) of this word shall change only during the execution of a
hardware reset. Especially Bit 13 shows cable detection 1 80 cable or 0 40 cable.
8.6.27 Word 128: Security status
Word 128 shall have the content described for word 128 of the IDENTIFY DEVICE command. Support of this
word is mandatory if the Security feature set is supported.
Swissbit AG
Industriestrasse 4
CH-9552 Bronschhofen
Switzerland
Bit 15 0
Bit 14 1
Bit 13 1
Bit 12-8
Bit 12 0
Bit 11 0
Bit 10-9 These bits indicate how Device 1 determined the device number:
Bit 8
Bit 7-0
Bit 7
Bit 6 0
Bit 5 0
Bit 4 0
Bit 3 0
Bit 2-1
Bit 0
Bit 15-9 0 Reserved
Bit 8
Bit 7-6 0 Reserved
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
00 = Reserved.
01
10
11
00 = Reserved.
01
10
11
0
1
1
1
1
1
Shall be cleared to zero.
Shall be set to one.
= device detected CBLID- above ViH  80 wired cable
= device detected CBLID- below ViL
Device 1 hardware reset result. Device 0 shall clear these bits to zero.
Device 1 shall set these bits as follows:
Reserved.
= Device 1 did not assert PDIAG-
= Device 1 asserted PDIAG-.
= a jumper was used.
= the CSEL signal was used.
= some other method was used or the method is unknown.
Shall be set to one.
Device 0 hardware reset result. Device 1 shall clear these bits to zero. Device 0 shall
set these bits as follows:
Reserved.
= Device 0 does not respond when Device 1 is selected.
= Device 0 responds when Device 1 is selected.
= Device 0 did not detect the assertion of DASP-.
= Device 0 detected the assertion of DASP-.
= Device 0 did not detect the assertion of PDIAG-.
= Device 0 detected the assertion of PDIAG-.
= Device 0 failed diagnostics.
= Device 0 passed diagnostics.
These bits indicate how Device 0 determined the device number:
= a jumper was used.
= the CSEL signal was used.
= some other method was used or the method is unknown.
Shall be set to one.
Security level 0 = High, 1 = Maximum
1 = Enhanced security erase supported
1 = Security count expired
1 = Security frozen
1 = Security locked
1 = Security enabled
1 = Security supported