AD7194 Analog Devices, AD7194 Datasheet - Page 24

no-image

AD7194

Manufacturer Part Number
AD7194
Description
8-Channel, 4.8 kHz, Ultralow Noise, 24-Bit Sigma-Delta ADC with PGA
Manufacturer
Analog Devices
Datasheet

Specifications of AD7194

Resolution (bits)
24bit
# Chan
8
Sample Rate
n/a
Interface
Ser,SPI
Analog Input Type
Diff-Uni
Ain Range
(2Vref/PGA Gain) p-p
Adc Architecture
Sigma-Delta
Pkg Type
CSP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7194BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD7194
CONFIGURATION REGISTER
RS2, RS1, RS0 = 010; Power-On/Reset = 0x000117
The configuration register is a 24-bit register from which data
can be read or to which data can be written. This register is
used to configure the ADC for unipolar or bipolar mode, to
enable or disable the buffer, to enable or disable the burnout
currents, to select the gain, and to select the analog input
channel.
CON23
Chop(0)
CON15
CH7(0)
CON7
Burn(0)
CON22
0(0)
CON14
CH6(0)
CON6
REFDET(0)
CON21
0(0)
CON13
CH5(0)
CON5
0(0)
CON20
REFSEL(0)
CON12
CH4(0)
CON4
BUF(1)
Rev. 0 | Page 24 of 56
CON19
0(0)
CON11
CH3(0)
CON3
U/B (0)
Table 21 outlines the bit designations for the configuration register.
CON0 through CON23 indicate the bit locations. CON denotes
that the bits are in the configuration register. CON23 denotes
the first bit of the data stream. The number in parentheses
indicates the power-on/reset default status of that bit.
CON18
Pseudo(0)
CON10
CH2(0)
CON2
G2(1)
CON17
0(0)
CON9
CH1(0)
CON1
G1(1)
CON16
Temp(0)
CON8
CH0(1)
CON0
G0(1)

Related parts for AD7194