S25FL004K Meet Spansion Inc., S25FL004K Datasheet - Page 50

no-image

S25FL004K

Manufacturer Part Number
S25FL004K
Description
4-mbit / 8-mbit / 16-mbit Cmos 3.0 Volt Flash Memory With 104-mhz Spi Serial Peripheral Interface Multi I/o Bus
Manufacturer
Meet Spansion Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S25FL004K0XMFI011
Manufacturer:
SIEMENS
Quantity:
144
Part Number:
S25FL004K0XMFI011
Manufacturer:
SPANSION
Quantity:
20 000
7.26
50
Release from Deep Power-down / Device ID (ABh)
The Release from Deep Power-down / Device ID instruction is a multi-purpose instruction. It can be used to
release the device from the deep power-down state, or obtain the devices electronic identification (ID)
number.
To release the device from the deep power-down state, the instruction is issued by driving the CS# pin low,
shifting the instruction code “ABh” and driving CS# high as shown in
down will take the time duration of t
device will resume normal operation and other instructions are accepted. The CS# pin must remain high
during the t
When used only to obtain the Device ID while not in the deep power-down state, the instruction is initiated by
driving the CS# pin low and shifting the instruction code “ABh” followed by 3-dummy bytes. The Device ID bits
are then shifted out on the falling edge of CLK with most significant bit (MSB) first. The Device ID values for
the S25FL004K/S25FL008K/S25FL016K is listed in Manufacturer and Device Identification table. The Device
ID can be read continuously. The instruction is completed by driving CS# high.
When used to release the device from the deep power-down state and obtain the Device ID, the instruction is
the same as previously described, and shown in
remain high for a time duration of t
other instructions will be accepted. If the Release from Deep Power-down / Device ID instruction is issued
while an Erase, Program or Write cycle is in process (when BUSY equals 1) the instruction is ignored and will
not have any effects on the current cycle.
CLK
CS#
SO
SI
= MSB
Mode 3
Mode 0
CLK
CS#
SO
SI
Figure 7.30 Release from Deep Power-down / Device ID Instruction Sequence Diagram
RES1
Mode 3
Mode 0
0
time duration.
1
Figure 7.29 Release from Deep Power-down Instruction Sequence
Instruction (ABh)
2
0
High Impedance
3
S25FL004K / S25FL008K / S25FL016K
4
1
Instruction (ABh)
5
2
High Impedance
6
RES2
3
RES1
7 8
23 22 21
4
. After this time duration the device will resume normal operation and
(Section 8.6, AC Electrical Characteristics on page
9
5
3 Dummy Bytes
D a t a
10
6
Figure
7
28 29 30 31 32 33 34 35 36 37 38
3
2
S h e e t
7.30, except that after CS# is driven high it must
Deep Power-down Current
1
0
7
t
RES1
6
Device ID
Figure
5
S25FL004K-016K_00_02 July 14, 2011
4
Deep Power-down Current
7.29. Release from deep power-
3
2
1
Stand-by Current
0
Mode 3
Mode 0
Mode 3
Mode 0
t
RES2
64) before the
Stand-by Current

Related parts for S25FL004K