M3062GF8NGP#U5 Renesas Electronics America, M3062GF8NGP#U5 Datasheet - Page 202

MCU 3V 64K PB FREE 100-LQFP

M3062GF8NGP#U5

Manufacturer Part Number
M3062GF8NGP#U5
Description
MCU 3V 64K PB FREE 100-LQFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/60r
Datasheet

Specifications of M3062GF8NGP#U5

Core Processor
M16C/60
Core Size
16-Bit
Speed
10MHz
Connectivity
SIO, UART/USART
Peripherals
DMA, WDT
Number Of I /o
85
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
100-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M3062GF8NGP#U5M3062GF8NGP
Manufacturer:
MITSUBISHI
Quantity:
20 000
Company:
Part Number:
M3062GF8NGP#U5M3062GF8NGP#D5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M3062GF8NGP#U5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
CPU Rewrite Mode (Flash Memory Version)
Rev.1.1
Figure 1.29.7. Full status check flowchart and remedial procedure for errors
Full Status Check
End (block erase, program)
By performing full status check, it is possible to know the execution results of erase and program
operations. Figure 1.29.7 shows a full status check flowchart and the action to be taken when each
error occurs.
Note: When one of SR5 to SR4 is set to 1, none of the program, erase all blocks, and
Read status register
SR4=1 and SR5
block erase commands is accepted. Execute the clear status register command
(50
SR5=0?
SR4=0?
=1 ?
16
) before executing these commands.
YES
YES
NO
YES
NO
NO
(Set an address to even
when reading the status
register)
Block erase error
sequence error
Program error
Command
Execute the clear status register command (50
to clear the status register. Try performing the
operation one more time after confirming that the
command is entered correctly.
Should a block erase error occur, the block in error
cannot be used.
Execute the read lock bit status command (71
to see if the block is locked. After removing lock,
execute write operation in the same way. If the
error still occurs, the page in error cannot be
used.
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
M3062GF8NFP/GP
Mitsubishi microcomputers
16
16
)
)
199

Related parts for M3062GF8NGP#U5