D12312SVF20V Renesas Electronics America, D12312SVF20V Datasheet - Page 525

IC H8S/2312S MCU ROMLESS 100QFP

D12312SVF20V

Manufacturer Part Number
D12312SVF20V
Description
IC H8S/2312S MCU ROMLESS 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of D12312SVF20V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
70
Program Memory Type
ROMless
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
For Use With
EDK2329 - DEV EVALUATION KIT H8S/2329
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12312SVF20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
A TEI interrupt is requested when the TEND flag is set to 1 while the TEIE bit is set to 1. The
TEND flag is cleared at the same time as the TDRE flag. Consequently, if a TEI interrupt and a
TXI interrupt are requested simultaneously, the TXI interrupt may be accepted first, with the result
that the TDRE and TEND flags are cleared. Note that the TEI interrupt will not be accepted in
this case.
12.5
The following points should be noted when using the SCI.
Relation between Writes to TDR and the TDRE Flag: The TDRE flag in SSR is a status flag
that indicates that transmit data has been transferred from TDR to TSR. When the SCI transfers
data from TDR to TSR, the TDRE flag is set to 1.
Data can be written to TDR regardless of the state of the TDRE flag. However, if new data is
written to TDR when the TDRE flag is cleared to 0, the data stored in TDR will be lost since it has
not yet been transferred to TSR. It is therefore essential to check that the TDRE flag is set to 1
before writing transmit data to TDR.
Operation when Multiple Receive Errors Occur Simultaneously: If a number of receive errors
occur at the same time, the state of the status flags in SSR is as shown in table 12.13. If there is an
overrun error, data is not transferred from RSR to RDR, and the receive data is lost.
Table 12.13 State of SSR Status Flags and Transfer of Receive Data
1
0
0
1
1
0
1
Notes:
RDRF
X: Receive data is not transferred from RSR to RDR.
ORER
1
0
0
1
1
0
1
SSR Status Flags
Usage Notes
: Receive data is transferred from RSR to RDR.
0
1
0
1
0
1
1
FER
0
0
1
0
1
1
1
PER
X
X
X
X
Receive Data Transfer
from RSR to RDR
Section 12 Serial Communication Interface (SCI)
Rev.7.00 Feb. 14, 2007 page 491 of 1108
Overrun error
Framing error
Parity error
Overrun error + framing error
Overrun error + parity error
Framing error + parity error
Overrun error + framing error +
parity error
Receive Error Status
REJ09B0089-0700

Related parts for D12312SVF20V