Specifications of D12312SVF20V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
70
Program Memory Type
ROMless
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
For Use With
EDK2329 - DEV EVALUATION KIT H8S/2329
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12312SVF20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 2 CPU
2.8.3
The exception-handling state is a transient state that occurs when the CPU alters the normal
processing flow due to a reset, interrupt, or trap instruction. The CPU fetches a start address
(vector) from the exception vector table and branches to that address.
(1) Types of Exception Handling and Their Priority
Exception handling is performed for traces, resets, interrupts, and trap instructions. Table 2.7
indicates the types of exception handling and their priority. Trap instruction exception handling is
always accepted, in the program execution state.
Exception handling and the stack structure depend on the interrupt control mode set in SYSCR.
Table 2.7
Priority
High
Low
Notes: 1. Traces are enabled only in interrupt control mode 2. Trace exception-handling is not
Rev.7.00 Feb. 14, 2007 page 64 of 1108
REJ09B0089-0700
2. Interrupts are not detected at the end of the ANDC, ORC, XORC, and LDC instructions,
3. Trap instruction exception handling is always accepted, in the program execution state.
Exception-Handling State
executed at the end of the RTE instruction.
or immediately after reset exception handling.
Type of Exception
Reset
Trace
Interrupt
Trap instruction
Exception Handling Types and Priority
Detection Timing
Synchronized with clock
End of instruction
execution or end of
exception-handling
sequence *
End of instruction
execution or end of
exception-handling
sequence *
When TRAPA instruction
is executed
1
2
Start of Exception Handling
Exception handling starts
immediately after a low-to-high
transition at the RES pin, or
when the watchdog timer
overflows.
When the trace (T) bit is set to
1, the trace starts at the end of
the current instruction or current
exception-handling sequence.
When an interrupt is requested,
exception handling starts at the
end of the current instruction or
current exception-handling
sequence.
Exception handling starts when
a trap (TRAPA) instruction is
executed *