R4F24269NVFQV Renesas Electronics America, R4F24269NVFQV Datasheet - Page 1263

MCU 256KB FLASH 64K 144-LQFP

R4F24269NVFQV

Manufacturer Part Number
R4F24269NVFQV
Description
MCU 256KB FLASH 64K 144-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2400r
Datasheet

Specifications of R4F24269NVFQV

Core Processor
H8S/2600
Core Size
16/32-Bit
Speed
33MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, SSU, UART/USART
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
96
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R4F24269NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
R4F24269NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
H8S/2426, H8S/2426R, H8S/2424 Group
Notes:
REJ09B0466-0350 Rev. 3.50
Jul 09, 2010
1. When programming is to be performed multiple times on a system, reduce the effective number of
2. If an erase error occurs during erasure, execute the clear status command and then the erase
*1. Determination of the number of times for programming/erasure operations.
*2. This is the number of times for which all electrical characteristics are guaranteed.
When the number of times for programming/erasure operations is n (n = 100), data can be erased
For example, if programming of 4 bytes is done 1024 times, each at a different address in a 4-
However, programming of any location in a block multiple times is not possible (overwriting is
programming operations by shifting the writing addresses in sequence and so on until the
remaining blank area is as small as possible and only then erasing the entire block once. For
example, if sets of 16 bytes are being programmed, erasing the block once after programming the
maximum number of sets (256) minimizes the effective number of programming operations.
We recommend keeping information on the number of times erasure is performed for each block,
and setting up the limit on the number of times.
command at least 3 times until the erase does not recur.
Number of times programming/erasure is performed in each block.
n times in each block.
kbyte per block, and the block is then erased, this counts as programming/erasure one time.
prohibited).
Section 25 Electrical Characteristics
Page 1233 of 1372