HD64F3067RF20 Renesas Electronics America, HD64F3067RF20 Datasheet - Page 555

IC H8 MCU FLASH 128K 100-QFP

HD64F3067RF20

Manufacturer Part Number
HD64F3067RF20
Description
IC H8 MCU FLASH 128K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD64F3067RF20

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
70
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
Package
100PQFP
Family Name
H8
Maximum Speed
20 MHz
Operating Supply Voltage
5 V
Data Bus Width
16|32 Bit
Number Of Programmable I/os
70
Interface Type
SCI
On-chip Adc
8-chx10-bit
On-chip Dac
2-chx8-bit
Number Of Timers
7
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3067RF20
Manufacturer:
HIT
Quantity:
610
Part Number:
HD64F3067RF20
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3067RF20
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD64F3067RF20V
Manufacturer:
RENESAS
Quantity:
1 000
Section 13 Serial Communication Interface
(3)
Error handling
Overrun error handling
Clear ORER flag to 0 in SSR
<End>
Figure 13.18 Sample Flowchart for Serial Receiving (2)
In receiving, the SCI operates as follows:
The SCI synchronizes with serial clock input or output and synchronizes internally.
Receive data is stored in RSR in order from LSB to MSB.
After receiving the data, the SCI checks that the RDRF flag is 0, so that receive data can be
transferred from RSR to RDR. If this check passes, the RDRF flag is set to 1 and the received
data is stored in RDR. If the checks fails (receive error), the SCI operates as shown in table
13.11.
When a receive error has been identified in the error check, subsequent transmit and receive
operations are disabled.
When the RDRF flag is set to 1, if the RIE bit is set to 1 in SCR, a receive-data-full interrupt
(RXI) is requested. If the ORER flag is set to 1 and the RIE bit in SCR is also set to 1, a
receive-error interrupt (ERI) is requested.
Rev. 4.00 Jan 26, 2006 page 531 of 938
REJ09B0276-0400

Related parts for HD64F3067RF20