DF61657CN35FTV Renesas Electronics America, DF61657CN35FTV Datasheet - Page 115

IC H8SX/1657 MCU FLASH 120TQFP

DF61657CN35FTV

Manufacturer Part Number
DF61657CN35FTV
Description
IC H8SX/1657 MCU FLASH 120TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8SX/1600r
Datasheet

Specifications of DF61657CN35FTV

Core Processor
H8SX
Core Size
32-Bit
Speed
35MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
82
Program Memory Size
768KB (768K x 8)
Program Memory Type
FLASH
Ram Size
24K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
120-TQFP, 120-VQFP
For Use With
3DK1657 - DEV EVAL KIT FOR H8SX/1657
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF61657CN35FTV
Manufacturer:
RENESAS
Quantity:
101
Part Number:
DF61657CN35FTV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
4.9
When performing stack-manipulating access, this LSI assumes that the lowest address bit is 0. The
stack should always be accessed by a word transfer instruction or a longword transfer instruction,
and the value of the stack pointer (SP: ER7) should always be kept even. Use the following
instructions to save registers:
• PUSH.W Rn (or MOV.W Rn, @-SP)
• PUSH.L ERn (or MOV.L ERn, @-SP)
Use the following instructions to restore registers:
• POP.W Rn (or MOV.W @SP+, Rn)
• POP.L ERn (or MOV.L @SP+, ERn)
Performing stack manipulation while SP is set to an odd value leads to an address error. Figure 4.4
shows an example of operation when the SP value is odd.
SP
[Legend]
CCR :
PC :
R1L :
SP :
Note: This diagram illustrates an example in which the interrupt control mode is 0, in advanced mode.
Usage Note
SP set to H'FFFEFF
Condition code register
Program counter
General register R1L
Stack pointer
TRAPA instruction executed
Figure 4.4 Operation when SP Value Is Odd
(Address error occurred)
SP
Data saved above SP
CCR
PC
MOV.B R1L, @-ER7 executed
SP
Rev. 2.00 Jun. 28, 2007 Page 89 of 864
Contents of CCR lost
Section 4 Exception Handling
R1L
PC
REJ09B0341-0200
H'FFFEFA
H'FFFEFB
H'FFFEFC
H'FFFEFD
H'FFFEFE
H'FFFEFF
Address