AT91SAM7SE256B-CUR Atmel, AT91SAM7SE256B-CUR Datasheet - Page 600

IC ARM7 MCU FLASH 256K 128-LQFP

AT91SAM7SE256B-CUR

Manufacturer Part Number
AT91SAM7SE256B-CUR
Description
IC ARM7 MCU FLASH 256K 128-LQFP
Manufacturer
Atmel
Series
AT91SAMr
Datasheet

Specifications of AT91SAM7SE256B-CUR

Core Processor
ARM7
Core Size
16/32-Bit
Speed
55MHz
Connectivity
EBI/EMI, I²C, SPI, SSC, UART/USART, USB
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
88
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Processor Series
SAM7SE256
Core
ARM7TDMI
Data Bus Width
32 bit
Data Ram Size
32 KB
Interface Type
SPI, USB
Maximum Clock Frequency
48 MHz
Number Of Programmable I/os
88
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Operating Temperature Range
- 40 C to + 85 C
Processor To Be Evaluated
AT91SAM7SE256B
Supply Current (max)
60 uA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7SE256B-CUR
Manufacturer:
Atmel
Quantity:
10 000
39.5.4
Figure 39-2. EOCx and DRDY Flag Behavior
600
(ADC_CHSR)
(ADC_SR)
(ADC_SR)
EOCx
DRDY
CHx
SAM7SE512/256/32 Preliminary
Conversion Results
Write the ADC_CR
with START = 1
When a conversion is completed, the resulting 10-bit digital value is stored in the Channel Data
Register (ADC_CDR) of the current channel and in the ADC Last Converted Data Register
(ADC_LCDR).
The channel EOC bit in the Status Register (ADC_SR) is set and the DRDY is set. In the case of
a connected PDC channel, DRDY rising triggers a data transfer request. In any case, either
EOC and DRDY can trigger an interrupt.
Reading one of the ADC_CDR registers clears the corresponding EOC bit. Reading ADC_LCDR
clears the DRDY bit and the EOC bit corresponding to the last converted channel.
If the ADC_CDR is not read before further incoming data is converted, the corresponding Over-
run Error (OVRE) flag is set in the Status Register (ADC_SR).
In the same way, new data converted when DRDY is high sets the bit GOVRE (General Overrun
Error) in ADC_SR.
The OVRE and GOVRE flags are automatically cleared when ADC_SR is read.
Conversion Time
Read the ADC_CDRx
Write the ADC_CR
with START = 1
Conversion Time
Read the ADC_LCDR
6222F–ATARM–14-Jan-11