PEF 24470 H V1.3 Infineon Technologies, PEF 24470 H V1.3 Datasheet - Page 82

no-image

PEF 24470 H V1.3

Manufacturer Part Number
PEF 24470 H V1.3
Description
IC MTSI-XL SWITCHING MQFP100
Manufacturer
Infineon Technologies
Series
SWITIr
Datasheet

Specifications of PEF 24470 H V1.3

Function
Switching IC
Interface
PCM, PLL
Number Of Circuits
1
Voltage - Supply
3.13 V ~ 3.47 V
Current - Supply
200mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
100-SQFP
Includes
Clock Shift, Data Rate Adaption, Multipoint Switching
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEF24470HV1.3X
SP000007617
PRELIMINARY
6.1
For the read and write access it is necessary to distinguish between a connection and
configuration command. The connection command register is used to establish a
connection (described in
configure the device, e.g. set the clock frequency.
If the ISTA1:RDY bit is set the connection command register is ready to receive data
from the µP interface. If the parameter register and the connection command register are
written the RDY bit will be reset from the internal controller. If the connection is
established the internal controller will set the RDY bit and the connection command
register is ready for the next write or read access. The ISTA1:RDY can be enabled to
generate an interrupt to indicate that the device is ready to receive the data, otherwise
the µP must poll the ISTA1:RDY bit.
The configuration command register works independent from the RDY bit.
Note: There must be a recovery time period of 120 ns after every configuration
Preliminary Data Sheet
command write access to the next write access (command or parameter
register).
Read and Write Access
Chapter
6.10) and the configuration registers are used to
73
PEF 20450 / 20470 / 24470
Programming the Device
2001-11-20