6.2
6.3
Table 6-1. System Control Register Map
October 09, 2007
Offset
0x01C
0x000
0x004
0x008
0x010
0x014
0x018
0x030
0x034
Name
DID0
DID1
DC0
DC1
DC2
DC3
DC4
PBORCTL
LDOPCTL
Initialization and Configuration
The PLL is configured using direct register writes to the RCC/RCC2 register. If the RCC2 register
is being used, the USERCC2 bit must be set and the appropriate RCC2 bit/field is used. The steps
required to successfully change the PLL-based system clock are:
1.
2.
3.
4.
5.
Register Map
Table 6-1 on page 59 lists the System Control registers, grouped by function. The offset listed is a
hexadecimal increment to the register’s address, relative to the System Control base address of
0x400F.E000.
Note:
of the Hibernation module see a normal "power on" sequence and the processor starts running
code. It can determine that it has been restarted from Hibernate mode by inspecting the
Hibernation module registers.
Bypass the PLL and system clock divider by setting the BYPASS bit and clearing the USESYS
bit in the RCC register. This configures the system to run off a “raw” clock source (using the
main oscillator or internal oscillator) and allows for the new PLL configuration to be validated
before switching the system clock to the PLL.
Select the crystal value (XTAL) and oscillator source (OSCSRC), and clear the PWRDN bit in
RCC/RCC2. Setting the XTAL field automatically pulls valid PLL configuration data for the
appropriate crystal, and clearing the PWRDN bit powers and enables the PLL and its output.
Select the desired system divider (SYSDIV) in RCC/RCC2 and set the USESYS bit in RCC. The
SYSDIV field determines the system frequency for the microcontroller.
Wait for the PLL to lock by polling the PLLLRIS bit in the Raw Interrupt Status (RIS) register.
Enable use of the PLL by clearing the BYPASS bit in RCC/RCC2.
Spaces in the System Control register space that are not used are reserved for future or
internal use by Luminary Micro, Inc. Software should not modify any reserved memory
address.
Type
R/W
R/W
RO
RO
RO
RO
RO
RO
RO
0x0000.30DF
0x3F00.0FC0
0x0000.C0FF
0x0000.7FFD
0x00FF.007F
0x0000.0000
0x030F.5037
Reset
-
-
Preliminary
Description
Device Identification 0
Device Identification 1
Device Capabilities 0
Device Capabilities 1
Device Capabilities 2
Device Capabilities 3
Device Capabilities 4
Brown-Out Reset Control
LDO Power Control