FDC37B77X SMSC Corporation, FDC37B77X Datasheet - Page 106

no-image

FDC37B77X

Manufacturer Part Number
FDC37B77X
Description
ENHANCED SUPER I/O CONTROLLER WITH WAKE UP FEATURES
Manufacturer
SMSC Corporation
Datasheet
Power management capabilities are provided for
the following logical devices: floppy disk, UART
1, UART 2 and the parallel port.
logical device, two types of power management
are provided; direct powerdown and auto
powerdown.
FDC Power Management
Direct power management is controlled by
CR22. Refer to CR22 for more information.
Auto Power Management is enabled by CR23-
B0.
powerdown when all of the following conditions
have been met:
1.
2.
3.
4.
An internal timer is initiated as soon as the auto
powerdown command is enabled. The part is
then powered down when all the conditions are
met.
Disabling the auto powerdown mode cancels the
timer and holds the FDC block out of auto
powerdown.
DSR From Powerdown
If DSR powerdown is used when the part is in
auto powerdown, the DSR powerdown will
override the auto powerdown. However, when
the part is awakened from DSR powerdown, the
The motor enable pins of register 3F2H are
inactive (zero).
The part must be idle; MSR=80H and INT =
0 (INT may be high even if MSR = 80H due
to polling interrupts).
The head unload timer must have expired.
The Auto powerdown timer (10msec) must
have timed out.
When set, this bit allows FDC to enter
POWER MANAGEMENT
For each
106
auto powerdown will once again become
effective.
Wake Up From Auto Powerdown
If the part enters the powerdown state through
the auto powerdown mode, then the part can be
awakened by reset or by appropriate access to
certain registers.
If a hardware or software reset is used then the
part will go through the normal reset sequence.
If the access is through the selected registers,
then the FDC resumes operation as though it
was never in powerdown. Besides activating the
RESET pin or one of the software reset bits in
the DOR or DSR, the following register
accesses will wake up the part:
1.
2.
3.
Once awake, the FDC will reinitiate the auto
powerdown timer for 10 ms.
powerdown again when all the powerdown
conditions are satisfied.
V
The FDC37B77x requires a 25 mA trickle supply
(V
programmable wake-up events in the PME
interface when V
FDC37B77x is not intended to provide wake-up
capabilities on standby current, V
connected to V
receiver, IR interface, the CIR run-time registers,
the PME configuration registers, and the PME
TR
TR
SUPPORT
)
Enabling any one of the motor enable bits
in the DOR register (reading the DOR does
not awaken the part).
A read from the MSR register.
A read or write to the Data register.
to
provide
CC
. V
CC
TR
sleep
powers the Consumer IR
is removed.
current
The
TR
for
part will
can be
If the
the

Related parts for FDC37B77X