pef20324 Infineon Technologies Corporation, pef20324 Datasheet - Page 21

no-image

pef20324

Manufacturer Part Number
pef20324
Description
Multichannel Network Interface Controller With 128 Channels Extended
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
pef20324H
Manufacturer:
JRC
Quantity:
2 000
Part Number:
pef20324HV2.2
Manufacturer:
ICTAMI
Quantity:
12 388
Table 2-5
Pin No.
2, 5…8,
11…13, 30,
33…36,
39…41,
45…48,
51…54,
148, 149,
152…156,
159
14, 29, 42,
160
28
Hardware Reference Manual
Symbol
AD(31:0)
C/BE(3:0) t/s
PAR
Pin Descriptions by Functional Block: PCI Interface
Type Description
t/s
t/s
Address/Data Bus
A bus transaction consists of an address phase
followed by one or more data phases.
When MUNICH128X is Master, AD(31:0) are outputs
in the address phase of a transaction. During the data
phases, AD(31:0) remain outputs for write
transactions, and become inputs for read
transactions.
When MUNICH128X is Slave, AD(31:0) are inputs in
the address phase of a transaction. During the data
phases, AD(31:0) remain inputs for write transactions,
and become outputs for read transactions.
AD(31:0) is sampled on the rising edge of CLK.
Command/Byte Enable
During the address phase of a transaction, C/BE(3:0)
define the bus command. During the data phase, C/
BE(3:0) are used as Byte Enables. The Byte Enables
are valid for the entire data phase and determine
which byte lanes carry meaningful data. C/BE0
applies to byte 0 (lsb) and C/BE3 applies to byte 3
(msb).
When MUNICH128X is Master, C/BE(3:0) are
outputs.
When MUNICH128X is Slave, C/BE(3:0) are inputs.
C/BE(3:0) is sampled on the rising edge of CLK.
Parity
PAR is even parity across AD(31:0) and C/BE(3:0).
PAR is stable and valid one clock after the address
phase. PAR has the same timing as AD(31:0) but
delayed by one clock.
When MUNICH128X is Master, PAR is output during
address phase and write data phases.
When MUNICH128X is Slave, PAR is output during
read data phases. Parity errors detected by the
MUNICH128X are indicated on PERR output. PAR is
sampled on the rising edge of CLK.
21
Pin Descriptions
PEB 20324
PEF 20324
04.99

Related parts for pef20324