Section 15 Serial Communication Interface with FIFO (SCIF)
In clocked synchronous serial communication, each data bit is output on the communication line
from one falling edge of the serial clock to the next. Data is guaranteed valid at the rising edge of
the serial clock.
In each character, the serial data bits are transmitted in order from the LSB (first) to the MSB
(last). After output of the MSB, the communication line remains in the state of the MSB.
In clocked synchronous mode, the SCIF receives data by synchronizing with the rising edge of the
serial clock.
(1)
The data length is fixed at eight bits. No parity bit can be added.
(2)
An internal clock generated by the on-chip baud rate generator by the setting of the C/A bit in
SCSMR and CKE[1:0] in SCSCR, or an external clock input from the SCK pin can be selected as
the SCIF transmit/receive clock.
When the SCIF operates on an internal clock, it outputs the clock signal at the SCK pin. Eight
clock pulses are output per transmitted or received character. When the SCIF is not transmitting or
receiving, the clock signal remains in the high state. When only receiving, the clock signal outputs
while the RE bit of SCSCR is 1 and the number of data in receive FIFO is more than the receive
FIFO data trigger number.
(3)
• SCIF Initialization (Clocked Synchronous Mode)
Before transmitting, receiving, or changing the mode or communication format, the software must
clear the TE and RE bits to 0 in the serial control register (SCSCR), then initialize the SCIF.
Clearing TE to 0 initializes the transmit shift register (SCTSR). Clearing RE to 0, however, does
not initialize the RDF, PER, FER, and ORER flags and receive data register (SCRDR), which
retain their previous contents.
Rev. 2.00 Dec. 09, 2005 Page 772 of 1152
REJ09B0191-0200
Transmit/Receive Formats
Clock
Transmitting and Receiving Data