w925e625 ETC-unknow, w925e625 Datasheet - Page 57

no-image

w925e625

Manufacturer Part Number
w925e625
Description
8-bit Cid Microcontroller
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
w925e625FG
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
CAS/DTAS Detection
In off-hook services (type II), the detection of CAS/DTAS will affect the quality of the call waiting
service. When the CAS/DTAS is sent from far end, sometimes the near end user maybe still talking.
The CPE must be able to detect the CAS/DTAS successfully in the presence of near end speech. To
detect CAS/DTAS from telephone hybrid receiver pair improves the detection. However in BT’s on-
hook CID system the CAS/DTAS detection is from Tip/Ring pair.
The dual tone alert signal is separated into high and low tones and detected by a high/low tone
detector. When the alert tone is recognized by the detector, the bit ALGO will go high and the rising
signal will set the bit ALGOF in CIDFG to produce the CID flag(CIDF). Figure 6-21 shows the guard
time waveform of detecting alert tone. The total recognition time is t
present detect time and t
where t
present/absent guard time is determined by guard-time timer which the input clock period is 0.858Ms.
When the alert tone is detected the internal signal ALGR will be set and the rising edge of ALGR
resets the guard-time timer and the timer starts up counting from 00H. As the content of the timer is
the same as the register CASPT, the timer stops counting and the bit ALGO will be set and the rising
edge of ALGO triggers the flag ALGOF to become high. The counting of tone absent time is similar to
the counting of tone present time but the falling edge of ALGR/ ALGO replaces the rising edge and the
CASAT replaces the CASPT. The bit ALGO is controlled by hardware only. The flag ALGOF is set by
rising edge of ALGO and cleared by software.
Vin
ALGR
ALGO
ALGOF
DA
*
1: Guard time timer is reset and starts to up count from 00H.
2: Guard time timer is reset and starts to up count from 00H.
3: The content of the guard-time timer reaches the content of ASPT/ASAT.
*ALGR is an internal signal in the uC.
+ Clear by software.
is the tone absent detect time and t
t
DP
Figure 6-21 Guard Time Waveform of Alert Tone Signal Detection
GP
1
t
REC
is the tone present guard time. The total absent guard time is t
t
GP
3
Dual Alert Tone Signal
+
- 57 -
GA
2
is the tone absent guard time. The tone
t
t
GA
DA
3
t
ABS
t
DP
1
Publication Release Date: July 4, 2005
REC
t
DA
=t
DP
+t
GP
W925E/C625
, where t
DP
Revision A10
ABS
is the tone
=t
DA
+t
GA

Related parts for w925e625