EP1C4 ALTERA [Altera Corporation], EP1C4 Datasheet - Page 19
EP1C4
Manufacturer Part Number
EP1C4
Description
Cyclone FPGA Family Data Sheet
Manufacturer
ALTERA [Altera Corporation]
Datasheet
1.EP1C4.pdf
(104 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
EP1C4F3246N
Manufacturer:
ALTERA
Quantity:
5 510
Company:
Part Number:
EP1C4F3246N
Manufacturer:
HARRIS
Quantity:
5 510
Company:
Part Number:
EP1C4F324C6
Manufacturer:
ALTERA
Quantity:
3
Part Number:
EP1C4F324C6
Manufacturer:
ALTERA
Quantity:
20 000
Company:
Part Number:
EP1C4F324C6N
Manufacturer:
ALTERA
Quantity:
5 510
Company:
Part Number:
EP1C4F324C6N
Manufacturer:
ALTERA
Quantity:
250
Altera Corporation
January 2007
migrating through different device densities. Dedicated row
interconnects route signals to and from LABs, PLLs, and M4K memory
blocks within the same row. These row resources include:
■
■
The direct link interconnect allows an LAB or M4K memory block to
drive into the local interconnect of its left and right neighbors. Only one
side of a PLL block interfaces with direct link and row interconnects. The
direct link interconnect provides fast communication between adjacent
LABs and/or blocks without using row interconnect resources.
The R4 interconnects span four LABs, or two LABs and one M4K RAM
block. These resources are used for fast row connections in a four-LAB
region. Every LAB has its own set of R4 interconnects to drive either left
or right.
interconnects can drive and be driven by M4K memory blocks, PLLs, and
row IOEs. For LAB interfacing, a primary LAB or LAB neighbor can drive
a given R4 interconnect. For R4 interconnects that drive to the right, the
primary LAB and right neighbor can drive on to the interconnect. For R4
interconnects that drive to the left, the primary LAB and its left neighbor
can drive on to the interconnect. R4 interconnects can drive other R4
interconnects to extend the range of LABs they can drive. R4
interconnects can also drive C4 interconnects for connections from one
row to another.
Direct link interconnects between LABs and adjacent blocks
R4 interconnects traversing four blocks to the right or left
Figure 2–9
shows R4 interconnect connections from an LAB. R4
MultiTrack Interconnect
Preliminary
2–13