HD6412350 Hitachi, HD6412350 Datasheet - Page 564

no-image

HD6412350

Manufacturer Part Number
HD6412350
Description
(HD6412350 / HD6432351) 16-BIT MICROCONTROLLER
Manufacturer
Hitachi
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6412350F10
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412350F20
Manufacturer:
RENESAS
Quantity:
648
Part Number:
HD6412350F20
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6412350F20
Manufacturer:
ST
0
Part Number:
HD6412350F20
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412350F20V
Manufacturer:
RENESAS
Quantity:
586
Part Number:
HD6412350F20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6412350F20V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6412350TE20
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6412350TE20
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412350TE20IV
Manufacturer:
DALLAS
Quantity:
2 874
Bit 5—Overrun Error (ORER): Indicates that an overrun error occurred during reception,
causing abnormal termination.
Bit 5
ORER
0
1
Notes: 1. The ORER flag is not affected and retains its previous state when the RE bit in SCR is
Bit 4—Framing Error (FER): Indicates that a framing error occurred during reception in
asynchronous mode, causing abnormal termination.
Bit 4
FER
0
1
Notes: 1. The FER flag is not affected and retains its previous state when the RE bit in SCR is
544
2. The receive data prior to the overrun error is retained in RDR, and the data received
2. In 2-stop-bit mode, only the first stop bit is checked for a value of 0; the second stop bit
cleared to 0.
subsequently is lost. Also, subsequent serial reception cannot be continued while the
ORER flag is set to 1. In clocked synchronous mode, serial transmission cannot be
continued, either.
cleared to 0.
is not checked. If a framing error occurs, the receive data is transferred to RDR but the
RDRF flag is not set. Also, subsequent serial reception cannot be continued while the
FER flag is set to 1. In clocked synchronous mode, serial transmission cannot be
continued, either.
Description
[Clearing condition]
When 0 is written to ORER after reading ORER = 1
[Setting condition]
When the next serial reception is completed while RDRF = 1
Description
[Clearing condition]
When 0 is written to FER after reading FER = 1
[Setting condition]
When the SCI checks whether the stop bit at the end of the receive data when
reception ends, and the stop bit is 0 *
2
(Initial value)*
(Initial value)*
1
1