HD6412350 Hitachi, HD6412350 Datasheet - Page 618

no-image

HD6412350

Manufacturer Part Number
HD6412350
Description
(HD6412350 / HD6432351) 16-BIT MICROCONTROLLER
Manufacturer
Hitachi
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6412350F10
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412350F20
Manufacturer:
RENESAS
Quantity:
648
Part Number:
HD6412350F20
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6412350F20
Manufacturer:
ST
0
Part Number:
HD6412350F20
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412350F20V
Manufacturer:
RENESAS
Quantity:
586
Part Number:
HD6412350F20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6412350F20V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6412350TE20
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6412350TE20
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412350TE20IV
Manufacturer:
DALLAS
Quantity:
2 874
Bit 1—Reserved: Read-only bit, always read as 1.
Bit 0—Smart Card Interface Mode Select (SMIF): Enables or disables the Smart Card interface
function.
Bit 0
SMIF
0
1
14.2.2
Note: * Only 0 can be written to bits 7 to 3, to clear these flags.
Bit 4 of SSR has a different function in Smart Card interface mode. Coupled with this, the setting
conditions for bit 2, TEND, are also different.
Bits 7 to 5—Operate in the same way as for the normal SCI. For details, see section 13.2.7, Serial
Status Register (SSR).
Bit 4—Error Signal Status (ERS): In Smart Card interface mode, bit 4 indicates the status of the
error signal sent back from the receiving end in transmission. Framing errors are not detected in
Smart Card interface mode.
Bit 4
ERS
0
1
Note: Clearing the TE bit in SCR to 0 does not affect the ERS flag, which retains its previous
598
Bit
Initial value :
R/W
state.
Serial Status Register (SSR)
Description
Smart Card interface function is disabled
Smart Card interface function is enabled
Description
[Clearing condition]
[Setting condition]
When the low level of the error signal is sampled
:
:
Upon reset, and in standby mode or module stop mode
When 0 is written to ERS after reading ERS = 1
R/(W)*
TDRE
7
1
R/(W)*
RDRF
6
0
R/(W)*
ORER
5
0
R/(W)*
ERS
4
0
R/(W)*
PER
3
0
TEND
2
1
R
MPB
1
0
R
(Initial value)
(Initial value)
MPBT
R/W
0
0