SE98ATP,547 NXP Semiconductors, SE98ATP,547 Datasheet - Page 19

IC TEMP SENSOR DDR 8-HWSON

SE98ATP,547

Manufacturer Part Number
SE98ATP,547
Description
IC TEMP SENSOR DDR 8-HWSON
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SE98ATP,547

Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Register Bank
Sensor Type
Internal
Sensing Temperature
-40°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
1.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-WSON (Exposed Pad), 8-HWSON
Temperature Threshold
Programmable
Full Temp Accuracy
+/- 1 C
Digital Output - Bus Interface
2-Wire, SMBus, I2C
Digital Output - Number Of Bits
11
Supply Voltage (max)
3.6 V
Supply Voltage (min)
1.7 V
Description/function
DDR Memory Module Temperature Sensor
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Current
250 uA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
568-4731-2
SE98ATP,147
NXP Semiconductors
SE98A_4
Product data sheet
Table 9.
Bit
7
6
5
4
3
2
Symbol
CTLB
AWLB
CEVNT
ESTAT
EOCTL
CVO
Configuration register (address 01h) bit description
Description
Critical Trip Lock bit.
This bit is initially cleared. When set, this bit will return a 1, and remains locked
until cleared by internal Power-on reset. This bit can be written with a single
write and do not require double writes.
Alarm Window Lock bit.
This bit is initially cleared. When set, this bit will return a 1 and remains locked
until cleared by internal power-on reset. This bit can be written with a single
write and does not require double writes.
Clear EVENT (write only).
When read, this register always returns zero.
EVENT Status (read only).
The actual event causing the EVENT can be determined from the Read
Temperature register. Interrupt Events can be cleared by writing to the
‘Clear EVENT’ bit (CEVNT). Writing to this bit will have no effect.
EVENT Output Control.
When either of the Critical Trip or Alarm Window lock bits is set, this bit cannot
be altered until unlocked.
Critical Event Only.
When the Critical Trip or Alarm Window lock bit is set, this bit cannot be
altered until unlocked.
0 — Critical Alarm Trip register is not locked and can be altered (default).
1 — Critical Alarm Trip register settings cannot be altered.
0 — Upper and Lower Alarm Trip registers are not locked and can be
altered (default).
1 — Upper and Lower Alarm Trip registers setting cannot be altered.
0 — No effect (default).
1 — Clears active EVENT in Interrupt mode. Writing to this register has no
effect in Comparator mode.
0 — EVENT output condition is not being asserted by this device (default).
1 — EVENT output pin is being asserted by this device due to Alarm
Window or Critical Trip condition.
0 — EVENT output disabled (default).
1 — EVENT output enabled.
0 — EVENT output on Alarm or Critical temperature event (default)
1 — EVENT only if temperature is above the value in the critical
temperature register
Rev. 04 — 25 November 2009
Advisory note:
– JEDEC specification requires only the Alarm Window lock bit to be set.
– Work-around: Clear both Critical Trip and Alarm Window lock bits.
– Future 1.7 V to 3.6 V SE98B will require only the Alarm Window lock
bit to be set.
DDR memory module temp sensor, 1.7 V to 3.6 V
…continued
© NXP B.V. 2009. All rights reserved.
SE98A
19 of 43

Related parts for SE98ATP,547