HD6417727F100C Renesas Electronics America, HD6417727F100C Datasheet - Page 174

IC SUPERH MPU ROMLESS 240QFP

HD6417727F100C

Manufacturer Part Number
HD6417727F100C
Description
IC SUPERH MPU ROMLESS 240QFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417727F100C

Core Processor
SH-3 DSP
Core Size
32-Bit
Speed
100MHz
Connectivity
FIFO, SCI, SIO, SmartCard, USB
Peripherals
DMA, LCD, POR, WDT
Number Of I /o
104
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.6 V ~ 2.05 V
Data Converters
A/D 6x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
240-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417727F100C
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 3 Memory Management Unit (MMU)
3.5
There are four MMU exceptions: TLB miss, TLB protection violation, TLB invalid, and initial
page write.
3.5.1
A TLB miss results when the logical address and the address array of the selected TLB entry are
compared and no match is found. TLB miss exception handling includes both hardware and
software operations.
Hardware Operations: In a TLB miss, the SH7727 hardware executes a set of prescribed
operations, as follows:
1. The VPN field of the logical address causing the exception is written to the PTEH register.
2. The logical address causing the exception is written to the TEA register.
3. Either exception code H'040 for a load access, or H'060 for a store access, is written to the
4. The PC value indicating the address of the instruction in which the exception occurred is
5. The contents of the status register (SR) at the time of the exception are written to the save
6. The mode (MD) bit in SR is set to 1 to place the SH7727 in the privileged mode.
7. The block (BL) bit in SR is set to 1 to mask any further exception requests.
8. The register bank (RB) bit in SR is set to 1.
9. The random counter (RC) field in the MMU control register (MMUCR) is incremented by 1
10. Execution branches to the address obtained by adding the value of the VBR contents and
Software (TLB Miss Handler) Operations: The software searches the page tables in external
memory and allocates the required page table entry. Upon retrieving the required page table entry,
software must execute the following operations:
1. Write the value of the physical page number (PPN) field and the protection key (PR), page size
Rev.6.00 Mar. 27, 2009 Page 116 of 1036
REJ09B0254-0600
EXPEVT register.
written to the save program counter (SPC). If the exception occurred in a delay slot, the PC
value indicating the address of the related delayed branch instruction is written to the SPC.
status register (SSR).
when all ways are checked for the TLB entry corresponding to the logical address at which the
exception occurred, and all ways are valid. If one or more ways are invalid, those ways are set
in RC in prioritized order from way 0 through way 1, way 2, and way 3.
H'00000400 to invoke the user-written TLB miss exception handler.
(SZ), cacheable (C), dirty (D), share status (SH), and valid (V) bits of the page table entry
MMU Exceptions
TLB Miss Exception

Related parts for HD6417727F100C