HD64F2134FA20 Renesas Electronics America, HD64F2134FA20 Datasheet - Page 458

no-image

HD64F2134FA20

Manufacturer Part Number
HD64F2134FA20
Description
IC H8S MCU FLASH 128K 80QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2100r
Datasheets

Specifications of HD64F2134FA20

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
IrDA, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
58
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
80-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2134FA20
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F2134FA20V
Manufacturer:
RENESAS
Quantity:
201
Section 15 Serial Communication Interface (SCI, IrDA)
Bit 6—Receive Data Register Full (RDRF): Indicates that the received data is stored in RDR.
Bit 6
RDRF
0
1
Note: RDR and the RDRF flag are not affected and retain their previous values when an error is
Bit 5—Overrun Error (ORER): Indicates that an overrun error occurred during reception,
causing abnormal termination.
Bit 5
ORER
0
1
Notes: 1. The ORER flag is not affected and retains its previous state when the RE bit in SCR is
Rev. 4.00 Jun 06, 2006 page 402 of 1004
REJ09B0301-0400
detected during reception or when the RE bit in SCR is cleared to 0.
If reception of the next data is completed while the RDRF flag is still set to 1, an overrun
error will occur and the receive data will be lost.
2. The receive data prior to the overrun error is retained in RDR, and the data received
cleared to 0.
subsequently is lost. Also, subsequent serial reception cannot be continued while the
ORER flag is set to 1. In synchronous mode, serial transmission cannot be continued,
either.
Description
[Clearing conditions]
[Setting condition]
When serial reception ends normally and receive data is transferred from RSR to RDR
Description
[Clearing condition]
When 0 is written in ORER after reading ORER = 1
[Setting condition]
When the next serial reception is completed while RDRF = 1 *
When 0 is written in RDRF after reading RDRF = 1
When the DTC is activated by an RXI interrupt and reads data from RDR
2
(Initial value) *
(Initial value)
1

Related parts for HD64F2134FA20