EP2S90F1508I4 Altera, EP2S90F1508I4 Datasheet - Page 23

IC STRATIX II FPGA 90K 1508-FBGA

EP2S90F1508I4

Manufacturer Part Number
EP2S90F1508I4
Description
IC STRATIX II FPGA 90K 1508-FBGA
Manufacturer
Altera
Series
Stratix® IIr
Datasheet

Specifications of EP2S90F1508I4

Number Of Logic Elements/cells
90960
Number Of Labs/clbs
4548
Total Ram Bits
4520488
Number Of I /o
902
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
1508-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Other names
544-1923
EP2S90F1508I4

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2S90F1508I4
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP2S90F1508I4
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2S90F1508I4
Manufacturer:
ALTERA
0
Part Number:
EP2S90F1508I4N
Manufacturer:
ALTERA
Quantity:
586
Part Number:
EP2S90F1508I4N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2S90F1508I4N
Manufacturer:
ALTERA
0
Company:
Part Number:
EP2S90F1508I4N
Quantity:
100
Altera Corporation
May 2007
Figure 2–11. ALM in Arithmetic Mode
While operating in arithmetic mode, the ALM can support simultaneous
use of the adder's carry output along with combinational logic outputs. In
this operation, the adder output is ignored. This usage of the adder with
the combinational logic output provides resource savings of up to 50% for
functions that can use this ability. An example of such functionality is a
conditional operation, such as the one shown in
equation for this example is:
To implement this function, the adder is used to subtract ‘Y’ from ‘X.’ If
‘X’ is less than ‘Y,’ the carry_out signal is ‘1.’ The carry_out signal is
fed to an adder where it drives out to the LAB local interconnect. It then
feeds to the LAB-wide syncload signal. When asserted, syncload
selects the syncdata input. In this case, the data ‘Y’ drives the
syncdata inputs to the registers. If ‘X’ is greater than or equal to ‘Y,’ the
syncload signal is de-asserted and ‘X’ drives the data port of the
registers.
datae0
datae1
dataf0
dataf1
datab
dataa
datad
datac
R = (X < Y) ? Y : X
4-Input
4-Input
4-Input
4-Input
LUT
LUT
LUT
LUT
carry_out
carry_in
Stratix II Device Handbook, Volume 1
adder0
adder1
D
D
reg0
reg1
Figure
Q
Q
Stratix II Architecture
2–12. The
To general or
To general or
To general or
To general or
local routing
local routing
local routing
local routing
2–15

Related parts for EP2S90F1508I4