TMPM333FDFG Toshiba, TMPM333FDFG Datasheet - Page 355

no-image

TMPM333FDFG

Manufacturer Part Number
TMPM333FDFG
Description
Microcontrollers (MCU) MCU w/ ARM Cortex-M3 512K FLASH, 32K SRAM
Manufacturer
Toshiba
Datasheets

Specifications of TMPM333FDFG

Processor Series
TX03
Core
ARM Cortex M3
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
512K
Rom Type
Flash
Ram (kbytes)
32K
Number Of Pins
100
Package
LQFP(14×14)
Vcc
3V
Cpu Mhz
40
Ssp (ch) Spi
-
I2c/sio (ch)
3
Uart/sio (ch)
3
Usb
-
Can
-
Ethernet
-
External Bus Interface
-
Cs/wait Controller (ch)
-
Dma Controller
-
10-bit Da Converter
-
10-bit Ad Converter
12
12-bit Ad Converter
-
16-bit Timer / Counter
10
Motor / Igbt Control
-
Real Time Clock
1
Watchdog Timer
Y
Osc Freq Detect
-
Clock Gear
Y
Low-power Hold Function
-
Remote Control Interface
-
Hardware Cec Controller
-
Comparators
-
Low-voltage Detector
-
Etm Hardware Trace
4-bit
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMPM333FDFG
Manufacturer:
Toshiba
Quantity:
10 000
12.4.5.2
12.4.5.3
12.4.5.4
AD conversion is under way is set to "1".
MOD2<ADBFHP>) showing that AD conversion is underway is set to "1". At that time, the value of the Busy
flag ADMOD0<ADBFN> for normal AD conversion before the start of top-priority AD conversions are
retained. The value of the conversion completion flag ADMOD0<EOCFN> for normal AD conversion before
the start of top-priority AD conversion is retained.
version is suspended, and restarts normal AD conversion after top-priority AD conversion is completed.
suspended, and the top-priority AD conversion starts; specifically, AD conversion (fixed-channel single con-
version) is executed for a channel designated by ADMOD2<HPADCH>. After the result of this top-priority
AD conversion is stored in the storage register ADREGSP, normal AD conversion is resumed.
conversion is discontinued when requirements for activation using a H/W activation resource are met, and
top-priority AD conversion (fixed-channel single conversion) starts for a channel designated by AD-
MOD2<HPADCH>. After the result of this top-priority AD conversion is stored in the storage register
ADREGSP, normal AD conversion is resumed.
is set to "1" during AIN2 conversion, AIN2 conversion is suspended, and conversion is performed for a
channel designated by <HPADCH> (AIN11 in the case shown below). After the result of conversion is stored
in ADREGSP, channel repeat conversion is resumed, starting from AIN2.
or channel scan conversion mode), write "0" to ADMOD0<REPEAT>. When ongoing AD conversion is
completed, the repeat conversion mode terminates, and ADMOD0<ADBFN> is set to "0".
Top-priority AD has been activated
Conversion Ch
When normal AD conversion starts, the AD conversion Busy flag (ADMOD0<ADBFN>) showing that
When top-priority AD conversion starts, the top-priority AD conversion Busy flag (AD-
If top-priority AD conversion has been activated during normal AD conversion, ongoing normal AD con-
If ADMOD2<HPADCE> is set to "1" during normal AD conversion, ongoing normal AD conversion is
If H/W activation of top-priority AD conversion is authorized during normal AD conversion, ongoing AD
For example, if channel repeat conversion is activated for channels AIN0 through AIN3 and if <HPADCE>
To stop the AD conversion operation in the repeat conversion mode (fixed-channel repeat conversion mode
Note:Normal AD conversion must not be activated when top-priority AD conversion is under way.
AD Conversion
Top-priority AD conversion during normal AD conversion
Stopping Repeat Conversion Mode
Ch0
Ch1
Ch2
Page 335
Ch11
Ch2
Ch3
TMPM333FDFG/FYFG/FWFG
Ch0