21.6.1 Wait Mode
21.6.2 Stop Mode
21.7 TIMB During Break Interrupts
MC68HC08QA24
Freescale Semiconductor
The TIMB remains active after the execution of a WAIT instruction. In
wait mode, the TIMB registers are not accessible by the CPU. Any
enabled CPU interrupt request from the TIMB can bring the MCU out of
wait mode.
If TIMB functions are not required during wait mode, reduce power
consumption by stopping the TIMB before executing the WAIT
instruction.
The TIMB is inactive after the execution of a STOP instruction. The
STOP instruction does not affect register conditions or the state of the
TIMB counter. TIMB operation resumes when the MCU exits stop mode.
A break interrupt stops the TIMB counter.
The system integration module (SIM) controls whether status bits in
other modules can be cleared during the break state. The BCFE bit in
the SIM break flag control register (SBFCR) enables software to clear
status bits during the break state. (See
Register.)
To allow software to clear status bits during a break interrupt, write a
logic 1 to the BCFE bit. If a status bit is cleared during the break state, it
remains cleared when the MCU exits the break state.
To protect status bits during the break state, write a logic 0 to the BCFE
bit. With BCFE at logic 0 (its default state), software can read and write
I/O registers during the break state without affecting status bits. Some
status bits have a 2-step read/write clearing procedure. If software does
the first step on such a bit before the break, the bit cannot change during
the break state as long as BCFE is at logic 0. After the break, doing the
second step clears the status bit.
Timer Interface B (TIMB)
10.8.3 SIM Break Flag Control
Timer Interface B (TIMB)
Technical Data