Description
2.0 V, 32/16 Kb Flash, Smartclock, 12-bit Adc
Manufacturer
Silicon Laboratories
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
c8051f410-GQ
Manufacturer:
SiliconL
Quantity:
1 928
Part Number:
c8051f410-GQ
Manufacturer:
SILICON
Quantity:
99
Part Number:
c8051f410-GQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
c8051f410-GQR
Manufacturer:
SiliconL
Quantity:
5 500
Part Number:
c8051f410-GQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
c8051f410-GQR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
c8051f410-GQR
0
Part Number:
c8051f410-GQR..
Manufacturer:
SILICON
Quantity:
15 000
Part Number:
c8051f410DK
Manufacturer:
Silicon Labs
Quantity:
135
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0:
Bit7
R
-
UNUSED. Read = 1, Write = don't care.
PSPI0: Serial Peripheral Interface (SPI0) Interrupt Priority Control.
This bit sets the priority of the SPI0 interrupt.
0: SPI0 interrupt set to low priority level.
1: SPI0 interrupt set to high priority level.
PT2: Timer 2 Interrupt Priority Control.
This bit sets the priority of the Timer 2 interrupt.
0: Timer 2 interrupt set to low priority level.
1: Timer 2 interrupt set to high priority level.
PS0: UART0 Interrupt Priority Control.
This bit sets the priority of the UART0 interrupt.
0: UART0 interrupt set to low priority level.
1: UART0 interrupt set to high priority level.
PT1: Timer 1 Interrupt Priority Control.
This bit sets the priority of the Timer 1 interrupt.
0: Timer 1 interrupt set to low priority level.
1: Timer 1 interrupt set to high priority level.
PX1: External Interrupt 1 Priority Control.
This bit sets the priority of the External Interrupt 1 interrupt.
0: External Interrupt 1 set to low priority level.
1: External Interrupt 1 set to high priority level.
PT0: Timer 0 Interrupt Priority Control.
This bit sets the priority of the Timer 0 interrupt.
0: Timer 0 interrupt set to low priority level.
1: Timer 0 interrupt set to high priority level.
PX0: External Interrupt 0 Priority Control.
This bit sets the priority of the External Interrupt 0 interrupt.
0: External Interrupt 0 set to low priority level.
1: External Interrupt 0 set to high priority level.
PSPI0
R/W
Bit6
SFR Definition 12.2. IP: Interrupt Priority
PT2
R/W
Bit5
PS0
R/W
Bit4
Rev. 1.0
PT1
R/W
Bit3
PX1
R/W
Bit2
C8051F410/1/2/3
PT0
R/W
Bit1
SFR Address:
PX0
R/W
Bit0
0xB8
10000000
Addressable
Reset Value
Bit
113