c8051f410 Silicon Laboratories, c8051f410 Datasheet - Page 63

no-image

c8051f410

Manufacturer Part Number
c8051f410
Description
2.0 V, 32/16 Kb Flash, Smartclock, 12-bit Adc
Manufacturer
Silicon Laboratories
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
c8051f410-GQ
Manufacturer:
SiliconL
Quantity:
1 928
Part Number:
c8051f410-GQ
Manufacturer:
SILICON
Quantity:
99
Part Number:
c8051f410-GQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
c8051f410-GQR
Manufacturer:
SiliconL
Quantity:
5 500
Part Number:
c8051f410-GQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
c8051f410-GQR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
c8051f410-GQR
0
Part Number:
c8051f410-GQR..
Manufacturer:
SILICON
Quantity:
15 000
Part Number:
c8051f410DK
Manufacturer:
Silicon Labs
Quantity:
135
5.4.
The ADC Programmable Window Detector continuously compares the ADC0 output registers to user-pro-
grammed limits, and notifies the system when a desired condition is detected. This is especially effective in
an interrupt-driven system, saving code space and CPU bandwidth while delivering faster system
response times. The window detector interrupt flag (AD0WINT in register ADC0CN) can also be used in
polled mode. The ADC0 Greater-Than (ADC0GTH, ADC0GTL) and Less-Than (ADC0LTH, ADC0LTL) reg-
isters hold the comparison values. The window detector flag can be programmed to indicate when mea-
sured data is inside or outside of the user-programmed limits, depending on the contents of the ADC0
Less-Than and ADC0 Greater-Than registers.
Bits7-4:
Bits3-2:
Bits1-0:
R/W
Bit7
Programmable Window Detector
AD0PWR3-0: ADC0 Burst Power-Up Time.
For BURSTEN = 0:
ADC0 power state controlled by AD0EN.
For BURSTEN = 1 and AD0EN = 1;
ADC0 remains enabled and does not enter the low power state.
For BURSTEN = 1 and AD0EN = 0:
ADC0 enters the low power state as specified in Table 5.3 and Table 5.4 and is enabled
after each convert start signal. The Power Up time is programmed according to the following
equation:
AD0TM1-0: ADC0 Tracking Mode Select Bits.
00: Reserved.
01: ADC0 is configured to Post-Tracking Mode.
10: ADC0 is configured to Pre-Tracking Mode.
11: ADC0 is configured to Dual-Tracking Mode (default).
AD0TK1-0: ADC0 Post-Track Time.
Post-Tracking time is controlled by AD0TK as follows:
00: Post-Tracking time is equal to 2 SAR clock cycles + 2 FCLK cycles.
01: Post-Tracking time is equal to 4 SAR clock cycles + 2 FCLK cycles.
10: Post-Tracking time is equal to 8 SAR clock cycles + 2 FCLK cycles.
11: Post-Tracking time is equal to 16 SAR clock cycles + 2 FCLK cycles.
AD0PWR
SFR Definition 5.6. ADC0TK: ADC0 Tracking Mode Select
R/W
Bit6
AD0PWR
=
Tstartup
---------------------- 1
R/W
Bit5
200ns
R/W
Bit4
or
Tstartup
Rev. 1.0
R/W
Bit3
AD0TM
=
R/W
Bit2
(
AD0PWR
C8051F410/1/2/3
R/W
Bit1
+
AD0TK
1
(bit addressable)
)200ns
R/W
Bit0
SFR Address:
Reset Value
11111111
0xBA
63