km416rd8as Samsung Semiconductor, Inc., km416rd8as Datasheet - Page 21

no-image

km416rd8as

Manufacturer Part Number
km416rd8as
Description
128mbit Rdram 256k X 16 Bit X 2*16 Dependent Banks Direct Rdramtm For Consumer Package
Manufacturer
Samsung Semiconductor, Inc.
Datasheet
KM416RD8AS
Precharge Mechanisms
Figure 13 shows an example of precharge with the ROWR
packet mechanism. The PRER command must occur a time
Figure 14 (top) shows an example of precharge with a RDA
command. A bank is activated with an ROWA packet on the
ROW pins. Then, a series of four dualocts are read with RD
commands in COLC packets on the COL pins. The fourth of
these commands is a RDA, which causes the bank to auto-
matically precharge when the final read has finished. The
timing of this automatic precharge is equivalent to a PRER
command in an ROWR packet on the ROW pins that is
offset a time t
command. The RDA command should be treated as a RD
command in a COLC packet as well as a simultaneous (but
offset) PRER command in an ROWR packet when analyzing
interactions with other packets.
Figure 14 (middle) shows an example of precharge with a
WRA command. As in the RDA example, a bank is acti-
vated with an ROWA packet on the ROW pins. Then, two
dualocts are written with WR commands in COLC packets
on the COL pins. The second of these commands is a WRA,
which causes the bank to automatically precharge when the
final write has been retired. The timing of this automatic
precharge is equivalent to a PRER command in an ROWR
packet on the ROW pins that is offset a time t
COLC packet that causes the automatic retire. The WRA
command should be treated as a WR command in a COLC
packet as well as a simultaneous (but offset) PRER
command in an ROWR packet when analyzing interactions
with other packets. Note that the automatic retire is triggered
by a COLC packet a time t
COL4
CTM/CFM
DQA7..0
ROW2
DQB7..0
..COL0
..ROW0
OFFP
T
0
ACT a0
T
1
T
from the COLC packet with the RDA
2
T
3
T
4
T
RTR
5
T
6
Figure 13: Precharge via PRER Command in ROWR Packet
t
T
t
RAS
after the COLC packet with
7
RC
T
8
T
9
T
10
T
11
T
12
T
13
OFFP
T
14
T
15
T
from the
16
T
17
T
18
T
19
Page 18
T
20
T
21
t
ACT command. This timing will serve as a baseline aginst
which the other precharge mechanisms can be compared.
the WR command unless the second COLC contains a RD
command to the same device. This is described in more
detail in Figure 17.
Figure 14 (bottom) shows an example of precharge with a
PREX command in an COLX packet. A bank is activated
with an ROWA packet on the ROW pins. Then, a series of
four dualocts are read with RD commands in COLC packets
on the COL pins. The fourth of these COLC packets
includes an COLX packet with a PREX command. This
causes the bank to precharge with timing equivalent to a
PRER command in an ROWR packet on the ROW pins that
is offset a time t
command.
T
RAS
22
T
23
T
after the ACT command, and a time t
PRER a5
24
T
25
T
26
T
27
T
28
T
OFFP
29
T
30
T
t
31
RP
from the COLX packet with the PREX
T
32
ACT b0
T
33
T
34
T
35
Target
Direct RDRAM
Rev. 0.9 July. 1999
T
36
T
37
T
38
T
39
T
40
RP
b0 = {Da,Ba,Rb}
T
a0 = {Da,Ba,Ra}
41
a5 = {Da,Ba}
before the next
T
42
T
43
T
44
T
45
T
46
T
47