C8051F060DK Silicon Laboratories Inc, C8051F060DK Datasheet - Page 60

DEV KIT FOR F060/F062/F063

C8051F060DK

Manufacturer Part Number
C8051F060DK
Description
DEV KIT FOR F060/F062/F063
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheet

Specifications of C8051F060DK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051F06x
Interface Type
USB
Silicon Manufacturer
Silicon Labs
Core Architecture
8051
Silicon Core Number
C8051F060
Silicon Family Name
C8051F06x
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051060, C8051F062 and C8051F063
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1214

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F060DK
Manufacturer:
Silicon Labs
Quantity:
135
C8051F060/1/2/3/4/5/6/7
60
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bits 3-2: AD0CM1-0: ADC0 Start of Conversion Mode Select.
Bit 1:
Bit 0:
AD0EN
R/W
Bit7
AD0EN: ADC0 Enable Bit.
0: ADC0 Disabled. ADC0 is in low-power shutdown.
1: ADC0 Enabled. ADC0 is active and ready for data conversions or calibrations.
AD0TM: ADC Track Mode Bit.
0: When the ADC is enabled, tracking is continuous unless a conversion is in process.
1: Tracking Defined by AD0CM1-0 bits.
AD0INT: ADC0 Conversion Complete Interrupt Flag.
This flag must be cleared by software.
0: ADC0 has not completed a data conversion since the last time this flag was cleared.
1: ADC0 has completed a data conversion.
AD0BUSY: ADC0 Busy Bit.
Read:
0: ADC0 Conversion is complete or a conversion is not currently in progress. AD0INT is set
to logic 1 on the falling edge of AD0BUSY.
1: ADC0 Conversion is in progress.
Write:
0: No Effect.
1: Initiates ADC0 Conversion if AD0CM1-0 = 00b.
If AD0TM = 0:
00: ADC0 conversion initiated on every write of ‘1’ to AD0BUSY.
01: ADC0 conversion initiated on overflow of Timer 3.
10: ADC0 conversion initiated on rising edge of external CNVSTR0.
11: ADC0 conversion initiated on overflow of Timer 2.
If AD0TM = 1:
00: Tracking starts with the write of ‘1’ to AD0BUSY and is followed by the conversion.
01: Tracking started by the overflow of Timer 3 and is followed by the conversion.
10: ADC0 conversion starts on rising CNVSTR0 edge.
11: Tracking started by the overflow of Timer 2 and is followed by the conversion.
See Figure 5.4 and Table 5.1 for conversion timing parameters.
AD0WINT: ADC0 Window Compare Interrupt Flag.
This bit must be cleared by software.
0: ADC0 Window Comparison Data match has not occurred since this flag was last cleared.
1: ADC0 Window Comparison Data match has occurred.
RESERVED: Write to 0b.
AD0TM
R/W
Bit6
AD0INT AD0BUSY
R/W
Bit5
Figure 5.9. ADC0CN: ADC0 Control Register
R/W
Bit4
AD0CM1
Rev. 1.2
R/W
Bit3
AD0CM0
R/W
Bit2
AD0WINT
R/W
Bit1
SFR Address:
SFR Page:
R/W
Bit0
-
Bit Addressable
0xE8
0
Reset Value
00000000