Z8F083ASJ020EG Zilog, Z8F083ASJ020EG Datasheet - Page 38

IC ENCORE XP MCU FLASH 8K 28SOIC

Z8F083ASJ020EG

Manufacturer Part Number
Z8F083ASJ020EG
Description
IC ENCORE XP MCU FLASH 8K 28SOIC
Manufacturer
Zilog
Series
Encore!®r
Datasheet

Specifications of Z8F083ASJ020EG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Peripherals
Brown-out Detect/Reset, LED, POR, PWM, WDT
Number Of I /o
23
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
28-SOIC (7.5mm Width)
Data Bus Width
8 bit
Data Ram Size
256 B
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
23
Number Of Timers
2
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
For Use With
770-1002 - ISP 4PORT ZILOG Z8 ENCORE! MCU269-4672 - KIT DEVELOPMENT F083A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Connectivity
-
Lead Free Status / Rohs Status
 Details
Other names
269-4558-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8F083ASJ020EG
Manufacturer:
Zilog
Quantity:
363
PS026308-1207
Note: Not to Scale
Internal Precision
Internal RESET
VDD = 0.0V
Oscillator
Oscillator
Crystal
signal
Voltage Brownout Reset
V
V
POR
VBO
The devices in the Z8 Encore! F083A Series provide low VBO protection. The VBO
circuit forces the device to the Reset state, when the supply voltage drops below the VBO
threshold voltage (unsafe level). While the supply voltage remains below the POR
threshold voltage (V
After the supply voltage exceeds the POR threshold voltage, the device progresses
through a full system reset sequence, as described in the POR section. Following POR, the
POR status bit in the reset status (RSTSTAT) register is set to 1.
displays VBO operation. For the VBO and POR threshold voltages (V
Electrical Characteristics
The POR level is greater than the VBO level by the specified hysteresis value. This
ensures that the device undergoes a POR after recovering from a VBO condition.
The VBO circuit is either enabled or disabled during STOP mode. Operations during
STOP mode is set by the
VBO_AO, see
Flash Option Bits
Figure 6. Power-On Reset Operation
POR
), the VBO circuit holds the device in reset.
VBO_AO
on page 177.
counter delay
POR
on page 119.
Flash option bit. For more details on configuring
Oscillator
optional XTAL
Start-up
counter delay
Z8 Encore!
Reset and Stop Mode Recovery
Product Specification
Figure 7
VBO
Execution
Program
®
on page 27
F083A Series
and V
VDD = 3.3 V
POR
), see
26