Z8F083ASJ020EG Zilog, Z8F083ASJ020EG Datasheet - Page 91

IC ENCORE XP MCU FLASH 8K 28SOIC

Z8F083ASJ020EG

Manufacturer Part Number
Z8F083ASJ020EG
Description
IC ENCORE XP MCU FLASH 8K 28SOIC
Manufacturer
Zilog
Series
Encore!®r
Datasheet

Specifications of Z8F083ASJ020EG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Peripherals
Brown-out Detect/Reset, LED, POR, PWM, WDT
Number Of I /o
23
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
28-SOIC (7.5mm Width)
Data Bus Width
8 bit
Data Ram Size
256 B
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
23
Number Of Timers
2
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
For Use With
770-1002 - ISP 4PORT ZILOG Z8 ENCORE! MCU269-4672 - KIT DEVELOPMENT F083A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Connectivity
-
Lead Free Status / Rohs Status
 Details
Other names
269-4558-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8F083ASJ020EG
Manufacturer:
Zilog
Quantity:
363
Table 47. Timer 0–1 High Byte Register (TxH)
Table 48. Timer 0–1 Low Byte Register (TxL)
Timer Control Register Definitions
BITS
FIELD
RESET
R/W
ADDR
BITS
FIELD
RESET
R/W
ADDR
PS026308-1207
Timer 0–1 High and Low Byte Registers
R/W
R/W
7
0
7
0
The timer input is used as a selectable counting source. It shares the same pin as the
complementary timer output. When selected by the GPIO alternate function registers, this
pin functions as a timer input in all modes except for the DUAL PWM OUTPUT mode.
For this mode, there is no timer input available.
The Timer 0–1 high and low byte (TxH and TxL) registers
contain the current 16-bit timer count value. When the timer is enabled, a read from TxH
causes the value in TxL to be stored in a temporary holding register. A read from TxL
always returns this temporary register content when the timer is enabled, however, when
the timer is disabled, a read from the TxL reads the TxL register content directly.
Writing to the timer high and low byte registers, while the timer is enabled is not
recommended. There are no temporary holding registers available for Write operations, so
simultaneous 16-bit writes are not possible. If either the timer high or low byte registers
are written during counting, the 8-bit written value is placed in the counter (high or low
byte) at the next clock edge. The counter continues counting from the new value.
TH and TL—Timer high and low bytes
These 2 bytes, {TH[7:0], TL[7:0]}, contain the current 16-bit timer count value.
R/W
R/W
6
0
6
0
R/W
R/W
5
0
5
0
R/W
R/W
4
0
4
0
F00H, F08H
F01H, F09H
TH
TL
R/W
R/W
3
0
3
0
R/W
R/W
Z8 Encore!
(Table 47
2
0
2
0
Product Specification
and
R/W
R/W
1
0
1
0
®
Table
F083A Series
48)
R/W
R/W
0
0
0
1
Timers
79

Related parts for Z8F083ASJ020EG