HD6417708SF60 Renesas Electronics America, HD6417708SF60 Datasheet - Page 332

IC SUPERH MPU ROMLESS 144LQFP

HD6417708SF60

Manufacturer Part Number
HD6417708SF60
Description
IC SUPERH MPU ROMLESS 144LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417708SF60

Core Processor
SH-2
Core Size
32-Bit
Speed
60MHz
Connectivity
EBI/EMI, SCI, SmartCard
Peripherals
POR, WDT
Number Of I /o
8
Program Memory Type
ROMless
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Ram Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417708SF60
Manufacturer:
HITACHI
Quantity:
2 400
Part Number:
HD6417708SF60
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417708SF60
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6417708SF60
Manufacturer:
HIT
Quantity:
330
Part Number:
HD6417708SF60I
Manufacturer:
ACCMICRO
Quantity:
144
Part Number:
HD6417708SF60V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417708SF60V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
11.3
11.3.1
Each of the three channels has a 32-bit timer counter (TCNT) and a 32-bit timer constant register.
The TCNT counts down. The auto-reload function enables synchronized counting and counting by
external events. Channel 2 has an input capture function.
11.3.2
Counter Operation: When the STR0–STR2 bits in the timer start register (TSTR) are set, the
corresponding timer counter (TCNT) starts counting. When a TCNT underflows (H'00000000
H'FFFFFFFF), the UNF flag of the corresponding timer control register (TCR) is set. At this time,
if the UNIE bit in TCR is 1, an interrupt request is sent to the CPU. Also at this time, the value is
copied from TCOR to TCNT and the down-count operation is continued.
The count operation is set as follows (figure 11.2):
1. Select the counter clock with the TPSC2–TPSC0 bits in the timer control register (TCR). If the
2. Use the UNIE bit in TCR to set whether to generate an interrupt when TCNT underflows.
3. When using the input capture function, set the ICPE bits in TCR, including the choice of
4. Set a value in the timer constant register (TCOR) (the cycle is the set value plus 1).
5. Set the initial value in the timer counter (TCNT).
6. Set the STR bit in the timer start register (TSTR) to 1 to start operation.
312
external clock is selected, set the TCLK pin to input mode with the TOCE bit in TOCR, and
select its edge with the CKEG1 and CKEG0 bits in TCR.
whether or not to use the interrupt function (channel 2 only).
TMU Operation
Overview
Basic Functions

Related parts for HD6417708SF60