Specifications of UPD78F0555MA-FAA-AX

Core Processor
78K/0
Core Size
8-Bit
Speed
10MHz
Connectivity
I²C, LIN, UART/USART
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
9
Program Memory Size
4KB (4K x 8)
Program Memory Type
FLASH
Ram Size
384 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
78K0/Kx2-L
9.4.3 Setting window open period of watchdog timer
(0080H). The outline of the window is as follows.
R01UH0028EJ0400 Rev.4.00
Sep 27, 2010
Set the window open period of the watchdog timer by using bits 6 and 5 (WINDOW1, WINDOW0) of the option byte
• If “ACH” is written to WDTE during the window open period, the watchdog timer is cleared and starts counting again.
• Even if “ACH” is written to WDTE during the window close period, an abnormality is detected and an internal reset
Example: If the window open period is 25%
Caution The first writing to WDTE after a reset release clears the watchdog timer, if it is made before the
The window open period to be set is as follows.
Counting
starts
signal is generated.
Cautions 1. The combination of WDCS2 = WDCS1 = WDCS0 = 0 and WINDOW1 = WINDOW0 = 0 is
overflow time regardless of the timing of the writing, and the watchdog timer starts counting again.
WINDOW1
Internal reset signal is generated
if ACH is written to WDTE.
1
0
0
1
Window close period (75%)
2. The watchdog timer continues its operation during self-programming and EEPROM
prohibited.
emulation of the flash memory. During processing, the interrupt acknowledge time is
delayed. Set the overflow time and window size taking this delay into consideration.
Table 9-4. Setting Window Open Period of Watchdog Timer
WINDOW0
0
1
0
1
25%
50%
75%
100%
Window Open Period of Watchdog Timer
Counting starts again when
ACH is written to WDTE.
Window open
period (25%)
Overflow
time
CHAPTER 9 WATCHDOG TIMER
368

Related parts for UPD78F0555MA-FAA-AX