L6460 STMicroelectronics, L6460 Datasheet - Page 56

MOSFET & Power Driver ICs SPI Config Stepper DC Multi Motor DRV

L6460

Manufacturer Part Number
L6460
Description
MOSFET & Power Driver ICs SPI Config Stepper DC Multi Motor DRV
Manufacturer
STMicroelectronics
Type
Full-Bridge Driverr
Datasheet

Specifications of L6460

Product
Half-Bridge Drivers
Rise Time
0.4 us
Fall Time
0.4 us
Supply Voltage (max)
38 V
Supply Voltage (min)
13 V
Supply Current
11 mA
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Number Of Drivers
4
Output Current
10 mA
Output Voltage
30 V
Package / Case
TQFP-64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L6460
Manufacturer:
MICROCHIP
Quantity:
998
Part Number:
L6460
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
L6460TR
Manufacturer:
STMicroelectronics
Quantity:
10 000
Power bridges
14
56/139
Power bridges
L6460 includes four H bridge power outputs (each one made by two independent half
bridges) that are configurable in several different configurations.
Each half bridge is protected against: over-current, over-temperature and short circuit to
ground, to supply or across the load. When an over current event occurs, all outputs are
turned off (after a filter time), and the over current bit is stored in the internal status register
that can be read through SPI.
Positive and negative voltage spikes, which occur when switching inductive loads, are
limited by integrated freewheeling diodes (see
Figure 14. H Bridge block diagram
During the start up procedure the bridges are in high impedance and after that they can be
enabled through SPI. When a fault condition happens, i.e. an over-temperature event, the
bridges return in their start-up condition and they need to be re-enabled from the micro
controller.
The bridges can use PWM signals internally generated or externally provided (supplied
through the GPIO pins). Internally generated PWM signals will run at approximately
31.25kHz with a duty cycle that, through serial interface, can be programmed and
incremented in steps of 1/(512*F
voltage when all bridges are switching, the four internally generated PWM signals are out-
of-phase.
Each half bridge will use the PWM signal selected by the respective
MtrXSelPWMSideY[1:0] (X stands for 1, 2, 3 or 4; Y stands for A or B) bits in the SPI, but if
two half bridges are configured as a full bridge, only the PWM signal chosen for side A will
be used to drive the resulting H bridge.
More in detail the PWM selection truth table will be as describe in the following tables:
Doc ID 17713 Rev 1
osc
). To reduce the peak current requested from supply
Figure
14).
L6460