UPD78F0413GA-GAM-AX NEC, UPD78F0413GA-GAM-AX Datasheet - Page 335

8BIT UC, 32K FLASH, 1KB RAM, LCD

UPD78F0413GA-GAM-AX

Manufacturer Part Number
UPD78F0413GA-GAM-AX
Description
8BIT UC, 32K FLASH, 1KB RAM, LCD
Manufacturer
NEC
Datasheet

Specifications of UPD78F0413GA-GAM-AX

Controller Family/series
UPD78F
No. Of I/o's
30
Ram Memory Size
1024Byte
Cpu Speed
10MHz
No. Of Timers
8
No. Of Pwm
RoHS Compliant
Core Size
8bit
Program Memory Size
32KB
Oscillator Type
External, Internal

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F0413GA-GAM-AX
Manufacturer:
ADI
Quantity:
882
Part Number:
UPD78F0413GA-GAM-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
14.1 Functions of Serial Interface UART6
(1) Operation stop mode
(2) Asynchronous serial interface (UART) mode
Serial interface UART6 has the following two modes.
This mode is used when serial communication is not executed and can enable a reduction in the power
consumption.
For details, see 14.4.1 Operation stop mode.
This mode supports the LIN (Local Interconnect Network)-bus. The functions of this mode are outlined below.
For details, see 14.4.2
generator.
Cautions 1. The T
Maximum transfer rate: 625 kbps
Two-pin configuration
TxD6/RxD6 pins can be selected from P112/P113 (default) or P13/P12 by using the registers.
Data length of communication data can be selected from 7 or 8 bits.
Dedicated internal 8-bit baud rate generator allowing any baud rate to be set
Transmission and reception can be performed independently (full duplex operation).
MSB- or LSB-first communication selectable
Inverted transmission operation
Sync break field transmission from 13 to 20 bits
More than 11 bits can be identified for sync break field reception (SBF reception flag provided).
2. If clock supply to serial interface UART6 is not stopped (e.g., in the HALT mode), normal
3. Set POWER6 = 1 and then set TXE6 = 1 (transmission) or RXE6 = 1 (reception) to start
4. TXE6 and RXE6 are synchronized by the base clock (f
5. Set transmit data to TXB6 at least one base clock (f
6. If data is continuously transmitted, the communication timing from the stop bit to the next
side. To use this function, the reception side must be ready for reception of inverted data.
operation continues. If clock supply to serial interface UART6 is stopped (e.g., in the STOP
mode), each register stops operating, and holds the value immediately before clock supply
was stopped. The T
stopped and outputs it. However, the operation is not guaranteed after clock supply is
resumed. Therefore, reset the circuit so that POWER6 = 0, RXE6 = 0, and TXE6 = 0.
communication.
transmission or reception again, set TXE6 or RXE6 to 1 at least two clocks of the base clock
after TXE6 or RXE6 has been cleared to 0. If TXE6 or RXE6 is set within two clocks of the
base clock, the transmission circuit or reception circuit may not be initialized.
start bit is extended two operating clocks of the macro. However, this does not affect the
result of communication because the reception side initializes the timing when it has
detected a start bit. Do not use the continuous transmission function if the interface is
used in LIN communication operation.
X
D6 output inversion function inverts only the transmission side and not the reception
Asynchronous serial interface (UART) mode and 14.4.3
T
R
CHAPTER 14 SERIAL INTERFACE UART6
X
X
D6: Transmit data output pin
D6: Receive data input pin
X
D6 pin also holds the value immediately before clock supply was
User’s Manual U18698EJ1V0UD
XCLK6
) after setting TXE6 = 1.
XCLK6
) set by CKSR6. To enable
Dedicated baud rate
335

Related parts for UPD78F0413GA-GAM-AX