GS1559CBE2 GENNUM, GS1559CBE2 Datasheet - Page 54

IC, DES, 48.5MHZ 20BIT 1.485GBPS BGA-100

GS1559CBE2

Manufacturer Part Number
GS1559CBE2
Description
IC, DES, 48.5MHZ 20BIT 1.485GBPS BGA-100
Manufacturer
GENNUM
Datasheet

Specifications of GS1559CBE2

Supply Voltage Range
1.71V To 1.89V, 3.13V To 3.47V
Operating Temperature Range
0°C To +70°C
Digital Ic Case Style
BGA
No. Of Pins
100
Termination Type
SMD
Control Interface
Serial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 4-13: Host Interface Description for EDH Calculation Range Registers
Register Name
AP_LINE_START_F0
Address: 012h
AP_LINE_END_F0
Address: 013h
AP_LINE_START_F1
Address: 014h
AP_LINE_END_F1
Address: 015h
Bit
15-10
9-0
15-10
9-0
15-10
9-0
15-10
9-0
Name
AP_LINE_START_F0[9:0]
AP_LINE_END_F0[9:0]
AP_LINE_START_F1[9:0]
AP_LINE_END_F1[9:0]
If the received video format does not correspond to 525 or 625 digital component
video standards as determined by the flywheel pixel and line counters, then one of
two schemes for determining the EDH calculation ranges will be employed:
1. Ranges will be based on the line and pixel ranges programmed by the host
2. In the absence of user-programmed calculation ranges, ranges will be
The registers available to the host interface for programming EDH calculation
ranges include active picture and full field line start and end positions for both
fields.
reset.
If any or all of these register values are zero, then the EDH CRC calculation ranges
will be determined from the flywheel generated H signal. The first active and full
field pixel will always be the first pixel after the SAV TRS code word. The last active
and full field pixel will always be the last pixel before the start of the EAV TRS code
words.
30572 - 7
interface; or
determined from the received TRS timing information.
Table 4-13
May 2007
shows the relevant registers, which default to '0' after device
Description
Not Used.
Field 0 Active Picture start line data used to set
EDH calculation range outside of SMPTE RP
165 values.
Not Used.
Field 0 Active Picture end line data used to set
EDH calculation range outside of SMPTE RP
165 values.
Not Used.
Field 1 Active Picture end line data used to set
EDH calculation range outside of SMPTE RP
165 values.
Not Used.
Field 1 Active Picture end line data used to set
EDH calculation range outside of SMPTE RP
165 values.
GS1559 Data Sheet
R/W
R/W
R/W
R/W
R/W
Default
54 of 73
0
0
0
0

Related parts for GS1559CBE2