OM13005,598 NXP Semiconductors, OM13005,598 Datasheet - Page 119

BOARD EVAL EM773 METER US PLUG

OM13005,598

Manufacturer Part Number
OM13005,598
Description
BOARD EVAL EM773 METER US PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13005,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6680
NXP Semiconductors
UM10415
User manual
10.11.2 Master Receiver mode
In the master receiver mode, a number of data bytes are received from a slave transmitter
(see
START condition has been transmitted, the interrupt service routine must load I2DAT with
the 7-bit slave address and the data direction bit (SLA+R). The SI bit in I2CON must then
be cleared before the serial transfer can continue.
When the slave address and the data direction bit have been transmitted and an
acknowledgment bit has been received, the serial interrupt flag (SI) is set again, and a
number of status codes in I2STAT are possible. These are 0x40, 0x48, or 0x38 for the
master mode and also 0x68, 0x78, or 0xB0 if the slave mode was enabled (AA = 1). The
appropriate action to be taken for each of these status codes is detailed in
a Repeated START condition (state 0x10), the I
transmitter mode by loading I2DAT with SLA+W.
Figure
24). The transfer is initialized as in the master transmitter mode. When the
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
2
C block may switch to the master
Chapter 10: EM773 I2C-bus interface
UM10415
© NXP B.V. 2010. All rights reserved.
Table
130. After
119 of 310