OM13005,598 NXP Semiconductors, OM13005,598 Datasheet - Page 219

BOARD EVAL EM773 METER US PLUG

OM13005,598

Manufacturer Part Number
OM13005,598
Description
BOARD EVAL EM773 METER US PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13005,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6680
NXP Semiconductors
UM10415
User manual
18.5.4 Blank check sector(s) (IAP)
18.5.5 Read Part Identification number (IAP)
18.5.6 Read Boot code version number (IAP)
Table 206. IAP Blank check sector(s) command
Table 207. IAP Read Part Identification command
Table 208. IAP Read Boot Code version number command
Command
Input
Return Code
Result
Description
Command
Input
Return Code
Result
Description
Command
Input
Return Code
Result
Description
Blank check sector(s)
Command code: 5310
Param0: Start Sector Number
Param1: End Sector Number (should be greater than or equal to start sector
number).
CMD_SUCCESS |
BUSY |
SECTOR_NOT_BLANK |
INVALID_SECTOR
Result0: Offset of the first non blank word location if the Status Code is
SECTOR_NOT_BLANK.
Result1: Contents of non blank word location.
This command is used to blank check a sector or multiple sectors of on-chip flash
memory. To blank check a single sector use the same "Start" and "End" sector
numbers.
Read part identification number
Command code: 5410
Parameters: None
CMD_SUCCESS |
Result0: Part Identification Number.
This command is used to read the part identification number.
Read boot code version number
Command code: 5510
Parameters: None
CMD_SUCCESS |
Result0: 2 bytes of boot code version number in ASCII format. It is to be
interpreted as <byte1(Major)>.<byte0(Minor)>
This command is used to read the boot code version number.
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
Chapter 18: EM773 Flash memory programming firmware
UM10415
© NXP B.V. 2010. All rights reserved.
219 of 310