XRT84L38IB Exar Corporation, XRT84L38IB Datasheet - Page 176

no-image

XRT84L38IB

Manufacturer Part Number
XRT84L38IB
Description
Network Controller & Processor ICs 8 Ch T1/E1 Framer
Manufacturer
Exar Corporation
Datasheet

Specifications of XRT84L38IB

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
XRT84L38
OCTAL T1/E1/J1 FRAMER
B
IT
N
UMBER
4
3
2
1
0
Received Sa6 = 1010
Received Sa6 = 1000
Received Sa6 = 001X
Received Sa6 = others
Received Sa6 = 0000
B
IT
N
AME
B
IT
R/W
R/W
R/W
R/W
R/W
T
YPE
Received Sa6 = 1010:
When this bit is 0:
A de-bounced Sa6 bit of value equal to '1010' has not been
received from the incoming serial data.
When this bit is 1:
A de-bounced Sa6 bit of value equal to '1010' has been received
from the incoming serial data.
Received Sa6 = 1000:
When this bit is 0:
A de-bounced Sa6 bit of value equal to '1000' has not been
received from the incoming serial data.
When this bit is 1:
A de-bounced Sa6 bit of value equal to '1000' has been received
from the incoming serial data.
Received Sa6 = 001X:
When this bit is 0:
A de-bounced Sa6 bit of value equal to '001X' has not been
received from the incoming serial data.
When this bit is 1:
A de-bounced Sa6 bit of value equal to '001X' has been received
from the incoming serial data.Note:X can be either 0 or 1.
Received Sa6 = others:
When this bit is 0:
A de-bounced Sa6 bit of value equal to anything but other than
'1111', '1110', '1100', '1000', '001X' and '0000' has not been
received from the incoming serial data.
When this bit is 1:
A de-bounced Sa6 bit of value equal to anything but other than
'1111', '1110', '1100', '1000', '001X' and '0000' has been received
from the incoming serial data.
Received Sa6 = 0000:
When this bit is 0:
A de-bounced Sa6 bit of value equal to '0000' has not been
received from the incoming serial data.
When this bit is 1:
A de-bounced Sa6 bit of value equal to '0000' has been received
from the incoming serial data.
156
B
IT
D
ESCRIPTION
REV. 1.0.1

Related parts for XRT84L38IB