TXC-04222-AIOG Transwitch Corporation, TXC-04222-AIOG Datasheet - Page 202

no-image

TXC-04222-AIOG

Manufacturer Part Number
TXC-04222-AIOG
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-04222-AIOG

Screening Level
Industrial
Package Type
BGA
Lead Free Status / Rohs Status
Not Compliant
June 2003
TEMx28
TXC-04222
TXC-04222-MB, Ed. 6
Address
X+104
X+105
X+106
X+107
7-6
7-0
7-0
7-0
Bit
5
4
3
2
1
0
Proprietary TranSwitch Corporation Information for use Solely by its Customers
FTBnFFE
FTAnFFE
1 second
FCnOOL
Transmit
Violation
Transmit
Violation
Transmit
Violation
Previous
FTnLOS
FTnLOC
Symbol
Counter
Counter
Counter
FTnAIS
Coding
Coding
Coding
(15-8)
(7-0)
(7-0)
Not used:
Transmit Channel n Line AIS Persistent One Second Alarm Indica-
tion: This bit position is set to 1 for the one-second interval, when the
transmit line AIS alarm indication is active, but did not become active in
the previous one second interval.
Transmit Channel n B Side Add Bus FIFO Persistent One Second
Alarm Indication: This bit position is set to 1 for the one-second inter-
val, when the transmit B side add bus FIFO alarm indication is active, but
did not become active in the previous one second interval.
Transmit Channel n A Side Add Bus FIFO Persistent One Second
Alarm Indication: This bit position is set to 1 for the one-second inter-
val, when the transmit A side add bus FIFO alarm indication is active, but
did not become active in the previous one second interval.
Channel n Test Analyzer Out Of Lock Persistent One Second Alarm:
This bit position is set to 1 for the one-second interval, when the PRBS
test analyzer out of lock alarm indication is active, but did not become
active in the previous one second interval.
Transmit Channel n Loss Of Signal Persistent One Second Alarm
Indication: This bit position is set to 1 for the one-second interval, when
the transmit loss of clock alarm indication is active, but did not become
active in the previous one second interval.
Transmit Channel n Loss Of Clock Persistent One Second Alarm
Indication: This bit position is set to 1 for the one-second interval, when
the transmit loss of clock alarm indication is active, but did not become
active in the previous one second interval.
Transmit Channel n Coding Violation Counter - Low Order Byte:
Low order byte of a 16-bit counter which counts the number of coding
errors that have occurred in the DS1 B8ZS or E1 HDB3 line code. This
low order byte must be read before the high order byte for the same
channel is read, which is located in the following address.
Transmit Channel n Coding Violation Counter - High order Byte:
High order byte of an 16 counter which counts the number of coding
errors that have occurred in the DS1 B8ZS or E1 HDB3 line codes. This
high order byte must be read after the low order byte for the same chan-
nel, which is located in the preceding address, but before the next read
of the low order byte for any channel.
Transmit Channel n Previous One Second Coding Violation
Counter - Low Order Byte: This counter holds the lower 8 bits of a 16
bit counter for coding violation counts that occurred in the previous one
second interval. This location is updated from the Coding Violation
counter at one second intervals.
DATA SHEET
- 202 of 246 -