TXC-04222-AIOG Transwitch Corporation, TXC-04222-AIOG Datasheet - Page 214

no-image

TXC-04222-AIOG

Manufacturer Part Number
TXC-04222-AIOG
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-04222-AIOG

Screening Level
Industrial
Package Type
BGA
Lead Free Status / Rohs Status
Not Compliant
June 2003
TEMx28
TXC-04222
TXC-04222-MB, Ed. 6
Address
X+11B
Bit
7
6
5
4
3
2
1
0
Proprietary TranSwitch Corporation Information for use Solely by its Customers
PAnTCODI A Side Drop Bus Channel n Tandem Connection ODI One Second
PAnTCRDI A Side Drop Bus Channel n Tandem Connection RDI One Second
PAnTCAIS
PAnTCUQ
PAnTCLM
PAnTCTM
PAnTCLL
Symbol
A Side Drop Bus Channel n Tandem Connection Loss Of Multiframe
One Second Alarm Indication: This bit position is set when the A side
TC loss of multiframe alarm indication has changed state in the last one
second interval or is 1 at the end of the interval. This bit is disabled if the
one second pulse is not applied. This indication does not cause an inter-
rupt.
A Side Drop Bus Channel n Tandem Connection Trail Trace Mes-
sage Loss Of Lock One Second Alarm Indication: This bit position is
set when the A side TC loss of lock alarm indication has changed state
in the last one second interval or is 1 at the end of the interval. This bit is
disabled if the one second pulse is not applied. This indication does not
cause an interrupt.
A Side Drop Bus Channel n Bus Tandem Connection Trail Trace
Message Mismatch One Second Alarm: This bit position is set when
the A side TC mismatch alarm indication has changed state in the last
one second interval or is 1 at the end of the interval. This bit is disabled if
the one second pulse is not applied. This indication does not cause an
interrupt.
A Side Drop Bus Channel n Tandem Connection AIS One Second
Alarm Indication: This bit position is set when the A side TC AIS alarm
indication has changed state in the last one second interval or is 1 at the
end of the interval. This bit is disabled if the one second pulse is not
applied. This indication does not cause an interrupt.
A Side Drop Bus Channel n Tandem Connection Unequipped One
Second Alarm Indication: This bit position is set when the A side TC
unequipped alarm indication has changed state in the last one second
interval or is 1 at the end of the interval. This bit is disabled if the one
second pulse is not applied. This indication does not cause an interrupt.
Alarm Indication: This bit position is set when the A side TC RDI alarm
indication has changed state in the last one second interval or is 1 at the
end of the interval. This bit is disabled if the one second pulse is not
applied. This indication does not cause an interrupt.
Alarm Indication: This bit position is set when the A side TC ODI alarm
indication has changed state in the last one second interval or is 1 at the
end of the interval. This bit is disabled if the one second pulse is not
applied. This indication does not cause an interrupt.
Not used:
DATA SHEET
- 214 of 246 -
Description