IC AVR MCU 4K 10MHZ 1.8V 32-QFN

ATMEGA48V-10MU

Manufacturer Part NumberATMEGA48V-10MU
DescriptionIC AVR MCU 4K 10MHZ 1.8V 32-QFN
ManufacturerAtmel
SeriesAVR® ATmega
ATMEGA48V-10MU datasheets
 

Specifications of ATMEGA48V-10MU

Core ProcessorAVRCore Size8-Bit
Speed10MHzConnectivityI²C, SPI, UART/USART
PeripheralsBrown-out Detect/Reset, POR, PWM, WDTNumber Of I /o23
Program Memory Size4KB (2K x 16)Program Memory TypeFLASH
Eeprom Size256 x 8Ram Size512 x 8
Voltage - Supply (vcc/vdd)1.8 V ~ 5.5 VData ConvertersA/D 8x10b
Oscillator TypeInternalOperating Temperature-40°C ~ 85°C
Package / Case32-VQFN Exposed Pad, 32-HVQFN, 32-SQFN, 32-DHVQFNPackage32MLF EP
Device CoreAVRFamily NameATmega
Maximum Speed10 MHzOperating Supply Voltage2.5|3.3|5 V
Data Bus Width8 BitNumber Of Programmable I/os23
Interface TypeSPI/TWI/USARTOn-chip Adc8-chx10-bit
Number Of Timers3Processor SeriesATMEGA48x
CoreAVR8Data Ram Size512 B
Maximum Clock Frequency10 MHzMaximum Operating Temperature+ 85 C
Mounting StyleSMD/SMT3rd Party Development ToolsEWAVR, EWAVR-BL
Minimum Operating Temperature- 40 CController Family/seriesAVR MEGA
No. Of I/o's23Eeprom Memory Size256Byte
Ram Memory Size512ByteCpu Speed10MHz
No. Of Timers3Rohs CompliantYes
For Use WithATSTK600-TQFP32 - STK600 SOCKET/ADAPTER 32-TQFPATSTK600-DIP40 - STK600 SOCKET/ADAPTER 40-PDIP770-1007 - ISP 4PORT ATMEL AVR MCU SPI/JTAGATAVRDRAGON - KIT DRAGON 32KB FLASH MEM AVRATAVRISP2 - PROGRAMMER AVR IN SYSTEMATJTAGICE2 - AVR ON-CHIP D-BUG SYSTEMLead Free Status / RoHS StatusLead free / RoHS Compliant
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
Page 241
242
Page 242
243
Page 243
244
Page 244
245
Page 245
246
Page 246
247
Page 247
248
Page 248
249
Page 249
250
Page 250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
Page 248/378

Download datasheet (8Mb)Embed
PrevNext
Figure 23-7. ADC Timing Diagram, Free Running Conversion
Table 23-1.
Condition
First conversion
Normal conversions, single ended
Auto Triggered conversions
23.5
Changing Channel or Reference Selection
The MUXn and REFS1:0 bits in the ADMUX Register are single buffered through a temporary
register to which the CPU has random access. This ensures that the channels and reference
selection only takes place at a safe point during the conversion. The channel and reference
selection is continuously updated until a conversion is started. Once the conversion starts, the
channel and reference selection is locked to ensure a sufficient sampling time for the ADC. Con-
tinuous updating resumes in the last ADC clock cycle before the conversion completes (ADIF in
ADCSRA is set). Note that the conversion starts on the following rising ADC clock edge after
ADSC is written. The user is thus advised not to write new channel or reference selection values
to ADMUX until one ADC clock cycle after ADSC is written.
If Auto Triggering is used, the exact time of the triggering event can be indeterministic. Special
care must be taken when updating the ADMUX Register, in order to control which conversion
will be affected by the new settings.
If both ADATE and ADEN is written to one, an interrupt event can occur at any time. If the
ADMUX Register is changed in this period, the user cannot tell if the next conversion is based
on the old or the new settings. ADMUX can be safely updated in the following ways:
a. When ADATE or ADEN is cleared.
b. During conversion, minimum one ADC clock cycle after the trigger event.
c. After a conversion, before the Interrupt Flag used as trigger source is cleared.
When updating ADMUX in one of these conditions, the new settings will affect the next ADC
conversion.
ATmega48/88/168
248
One Conversion
11
12
13
Cycle Number
ADC Clock
ADSC
ADIF
ADCH
ADCL
Conversion
Complete
ADC Conversion Time
Sample & Hold
(Cycles from Start of Conversion)
Next Conversion
1
2
3
4
Sign and MSB of Result
LSB of Result
Sample & Hold
MUX and REFS
Update
Conversion Time
(Cycles)
13.5
25
1.5
13
2
13.5
2545S–AVR–07/10