HD64F3644DV Renesas Electronics America, HD64F3644DV Datasheet - Page 355

IC H8/3644 MCU FLASH 64QFP

HD64F3644DV

Manufacturer Part Number
HD64F3644DV
Description
IC H8/3644 MCU FLASH 64QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Lr
Datasheet

Specifications of HD64F3644DV

Core Processor
H8/300L
Core Size
8-Bit
Speed
8MHz
Connectivity
SCI
Peripherals
PWM, WDT
Number Of I /o
53
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3644DV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
1
2
3
4
Figure 10.24 Example of Multiprocessor Data Reception Flowchart
Set bit MPIE to 1
OER + FER = 1?
OER + FER = 1?
and FER in SSR
and FER in SSR
Read bits OER
Read bits OER
Read bit RDRF
Read bit RDRF
Clear bit RE to
Continue data
Read receive
Read receive
data in RDR
data in RDR
RDRF = 1?
RDRF = 1?
reception?
0 in SCR3
Own ID?
in SCR3
in SSR
in SSR
Start
End
No
Yes
No
Yes
No
Yes
4
5
Yes
No
No
Yes
No
Yes
Receive error
processing
(A)
1.
2.
3.
4.
5.
Section 10 Serial Communication Interface
Set bit MPIE to 1 in SCR3.
Read bits OER and FER in the serial
status register (SSR) to determine if
there is an error. If a receive error has
occurred, execute receive error processing.
Read SSR and check that bit RDRF is
set to 1. If it is, read the receive data in
RDR and compare it with this receiver's
own ID. If the ID is not this receiver's,
set bit MPIE to 1 again. When the RDR
data is read, bit RDRF is cleared to 0
automatically.
Read SSR and check that bit RDRF is
set to 1, then read the data in RDR.
If a receive error has occurred, read bits
OER and FER in SSR to identify the error,
and after carrying out the necessary error
processing, ensure that bits OER and FER
are both cleared to 0. Reception cannot be
resumed if either of these bits is set to 1.
In the case of a framing error, a break can
be detected by reading the value of the
RXD pin.
Rev. 6.00 Sep 12, 2006 page 333 of 526
REJ09B0326-0600

Related parts for HD64F3644DV