78M6612-IMR/F Maxim Integrated Products, 78M6612-IMR/F Datasheet - Page 87

no-image

78M6612-IMR/F

Manufacturer Part Number
78M6612-IMR/F
Description
IC POWER MEASUREMENT AC 68-QFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of 78M6612-IMR/F

Mounting Style
SMD/SMT
Package / Case
QFN-68
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
78M6612-IMR/F/PD3
Quantity:
5 000
DS_6612_001
4.4.7.3 Other Measurement Parameters
MAINEDGE_X is useful for implementing a real-time clock based on the input AC signal. MAINEDGE_X is
the number of half-cycles accounted for in the last accumulated interval for the AC signal.
TEMP_RAW may be used by the MPU to monitor chip temperature or to implement temperature
compensation.
GAIN_ADJ is a scaling factor for measurements based on the temperature. GAIN_ADJ is controlled by
the MPU for temperature compensation.
4.4.7.4 Pulse Generation
WRATE controls the number of pulses that are generated per measured Wh and VARh quantities. The
lower WRATE is the slower the pulse rate for measured energy quantity. The measurement constant Kh
is derived from WRATE as the amount of energy measured for each pulse. That is, if Kh = 1Wh/pulse, a
power applied to the measurement unit of 120 V and 30 A results in one pulse per second. If the load is
240 V at 150 A, ten pulses per second will be generated.
The maximum pulse rate is 7.5 kHz.
The maximum time jitter is 67
pulse generator is monitored for 1 second, the peak jitter is 67 ppm. After 10 seconds, the peak jitter is
6.7 ppm.
The average jitter is always zero. If it is attempted to drive either pulse generator faster than its maximum
rate, it will simply output at its maximum rate without exhibiting any rollover characteristics. The actual
pulse rate, using WSUM as an example, is:
where F
Rev. 1.2
Address
Address
0x0F
0x73
0x71
0x19
0x11
CE
CE
S
RATE
= sampling frequency (2520.6 Hz), X = Pulse speed factor.
=
MAINEDGE_X
TEMP_RAW_X
WRATE
GAIN_ADJ
SAG_THR
WRATE
Name
Name
WSUM
2
46
µ
s and is independent of the number of pulses measured. Thus, if the
F
Default
S
Default
313000
486
16384
X
N/A
N/A
Hz
,
Description
Kh = VMAX *IMAX * 47.1132 / (WRATE * N
Wh/pulse. The default value results in a Kh of 3.2 Wh/pulse
when 2520 samples are taken in each accumulation interval
(and VMAX=600, IMAX = 52, X = 6).
The maximum value for WRATE is 2
Scales all voltage and current inputs. 16384 provides unity
gain.
The threshold for sag warnings. The default value is
equivalent to 80V RMS if VMAX = 600V. The LSB value is
VMAX * 4.255*10
Description
The number of zero crossings of the selected voltage in
the previous accumulation interval. Zero crossings are
either direction and are debounced.
Filtered, unscaled reading from the temperature sensor.
-7
V (peak).
15
– 1.
78M6612 Data Sheet
ACC
* X)
87

Related parts for 78M6612-IMR/F