Lead free / RoHS Compliant
ProASIC3/E Starter Kit User’s Guide and Tutorial
15. Connect the programming cable of the FlashPro3 programmer to the J1 shrouded and keyed header labeled FP3.
16. On the PC, run the FlashPro v3.3 software and connect to the programmer. Select ProASIC3E as the device family.
17. This concludes the testing of the board. Switch SW11 to the OFF position and remove the power connector from
The red line labeling pin 1 should be close to pin 1 on the header – no other orientation is possible.
Once the software has shown a connection, select Analyze Chain from the File menu.
If an error message of incorrect VJTAG is reported, then remove the jumper placed at J5 and place it instead at J12
across pins 11 and 12. It may safely be left there. Repeat the Analyze Chain command.
If a message appears indicating that an A3PE600 or A3P250 part (depending on the device fitted to the board) has
been detected, then the board has passed this test. Leave the silicon in place in the socket and move to the next step.
If a message of 11 or some other numeric indication appears, then record the message in a test log and fail the board.
Remove the silicon from the socket and place it in the safe silicon holding area.
J18.
Test Procedure for the A3PE-A3P-EVAL-BRD1