LMK03200ISQE/NOPB National Semiconductor, LMK03200ISQE/NOPB Datasheet - Page 21

IC CLOCK CONDITIONER PREC 48-LLP

LMK03200ISQE/NOPB

Manufacturer Part Number
LMK03200ISQE/NOPB
Description
IC CLOCK CONDITIONER PREC 48-LLP
Manufacturer
National Semiconductor
Type
Clock Conditionerr
Datasheet

Specifications of LMK03200ISQE/NOPB

Pll
Yes
Input
Clock
Output
LVDS, LVPECL
Number Of Circuits
1
Ratio - Input:output
1:9
Differential - Input:output
Yes/Yes
Frequency - Max
1.296GHz
Divider/multiplier
Yes/No
Voltage - Supply
3.15 V ~ 3.45 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-LLP
Frequency-max
1.296GHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LMK03200ISQETR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LMK03200ISQE/NOPB
Manufacturer:
NSC
Quantity:
72
The device now beings the frequency calibration routine,
when it completes the LD pin will go high since PLL_MUX was
programmed with the active high option for lock detect and
DLD_MODE2 = 1. When the LD pin goes high, or after 2 ms
have passed (the time for frequency calibration routine to
complete), step 2 is executed. Note that VCO_DIV = 0 was
not programmed to select VCO Divider since that is the de-
fault mode.
At this time the clock output frequency will be half the final
value because VCO_DIV = 2. If VCO_DIV was = 3, the clock
output frequencies would be a third the final value, etc.
Step 2
When R7 is updated to bypass the VCO divider the PLL will
loose lock until R15 can be updated again with the updated
PLL_N divider value.
Once the LD pin goes high again, the clock outputs will be
locked at 614.4 MHz and 307.2 MHz.
Program Register 0
DLD_MODE2 = 0 (Digital lock detect is normal)
0_DELAY_MODE = 1 (active 0-delay mode so that
programming R15 won't start frequency calibration
routine)
CLKout0_EN = 1 (keep same programming)
CLKout0_MUX = 0 (keep same programming)
Program Register 7
VCO_MUX = 2 (bypass VCO divider)
Program Register 15 (VCO Frequency = 1228.8 MHz)
PLL_N = 40 (VCO_DIV bypassed, must update PLL_N)
Program Register 0
0_DELAY_MODE = 0
CLKout0_EN = 1 (keep same programming)
CLKout0_MUX = 0 (keep same programming)